Minimum
setting
Factory
setting
Maximum
setting
Delay at signal
sec
5
60
255
Service plans
Minimum
setting
Factory
setting
Maximum
setting
Service plan A (operating hours)
hr
See remark
4000
See remark
Service plan B (operating hours)
hr
See remark
8000
See remark
Service plan C (operating hours)
hr
See remark
16000
See remark
Service plan D (operating hours)
hr
See remark
24000
See remark
Service plan I (operating hours)
hr
See remark
2000
See remark
Analogue signals
Minimum
setting
Factory
setting
Maximum
setting
Dp of oil separator (shut-down warning
level)
bar
0
0.8
1.0
Delay at signal, Dp of oil separator
sec
0
60
255
Dp of air filter:
Shut-down warning level
mbar
-85
-80
0
Shut-down level
mbar
-85
-85
0
Delay at signal, Dp of air filter
sec
0
60
255
Dp of DD filter
mbar
100
350
350
Delay at signal
sec
0
60
255
Remark
A number of service operations are grouped (Level A, Level B, ...). Each level stands for a number of service
operations to be carried out at the programmed intervals. Consult your Atlas Copco Service Centre.
Instruction book
APF192090
47
Содержание GA 160 VSD
Страница 1: ...GA 160 VSD APF192090 Instruction book ...
Страница 2: ......
Страница 61: ...Electric cabinet Cabinet with VSD Variable Speed Drive unit of GA 132 160 VSD Instruction book APF192090 59 ...
Страница 64: ...Instruction book 62 APF192090 ...
Страница 66: ...Figure A Instruction book 64 APF192090 ...
Страница 67: ...Figure B Instruction book APF192090 65 ...
Страница 70: ...Text on figure Instruction book 68 APF192090 ...
Страница 77: ...Ref Designation 29 Do not mix oil brands Instruction book APF192090 75 ...
Страница 92: ...See Oil specifications Instruction book 90 APF192090 ...
Страница 111: ......