• To test the display, press the key (2). During testing, the regulator will generate a series of
patterns on the display which enable the operator to check that each pixel still functions
normally; at the same time the LEDs are lit.
To test the Electronic Water Drains, press the arrow-down key until the option ‘Electron Drain’ is
followed by a horizontal arrow.
• Press the tabulator key (2) to activate the menu.
• Press the key ‘Strt’. Check that the valve opens for condensate discharge. Release the ‘Strt’
key after testing.
• Press the key ‘Back’ to return to the previous menu.
• Press the key ‘Menu’ (F1) to return to the submenu.
To run the regreasing program, press the arrow-down key until the option ‘Regreasing’ is
followed by a horizontal arrow. The compressor will run for a programmed time interval at a
programmed speed. After carrying out all service actions in the relevant ‘Service Plan’, reset the
service warning; see section
3.12 Modify parameters menu
Function
To modify a number of programmable settings:
• Compressor/motor settings (see section
Modifying compressor and motor settings
).
• Service plan settings (see section
Modifying service plan settings
• Clock function settings (see section
Modifying clock function settings
• Configuration settings (see section
Modifying configuration settings
3.13 Modifying compressor/motor settings
Control panel
Function
To modify a number of settings. Consult the menu flow in section
Procedure
Starting from the Main screen (see section
):
Instruction book
28
API161475