![Atlas Copco GA 11 VSD Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/atlas-copco/ga-11-vsd/ga-11-vsd_instruction-book_3001653035.webp)
‘Service Timer’
‘Running Hours’
‘hrs’
2130
‘Menu’
F1
F2
F3
• The screen shows the actual running hours.
• Press the tabulator key (2): a screen similar to the one below will appear:
‘Service Timer’
‘Level A’
‘hrs’
4000
‘Menu’
‘Mod.’
F1
F2
F3
• The screen indicates that the level for ‘Service Plan’ A is set at 4000 running hours.
• Press the ‘Mod.’ key (F2). The key ‘Lim’ (F2) can be used to find out the limitations for the
parameter. Use the arrow up and arrow down keys to modify the interval.
• Press the ‘Prog’ key (F1) to program the new setting or the ‘Canc’ key (F3) to cancel the
modification operation.
• The procedure to modify the Service plans B, C and D is similar.