![Atlas Copco GA 11 VSD Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/atlas-copco/ga-11-vsd/ga-11-vsd_instruction-book_3001653040.webp)
3.18 Modifying configuration settings
Control panel
Function
To modify a number of parameters. Consult the menu flow in section
Procedure
Starting from the Main screen (see
):
• Press the key ‘Menu’ (F1).
• Press the arrow down key (1) until ‘Modify Params’ is followed by an arrow pointing to the
right.
• Activate the menu by pressing tabulator key (2).
• Press the arrow down key (1) to scroll until ‘Configuration’ is followed by a horizontal arrow.
• Activate the menu by pressing tabulator key (2): the first item ‘Time’ will appear. If another
option is desired, scroll through the display until the option is followed by a horizontal arrow.
Select the option by pressing the tabulator key (2).
• For the option ‘Time’, the second line on the screen indicates the actual setting, e.g. 14:30.
To modify this setting, press the key ‘Mod.’ (F2); the first field (14) will flash.
• Use the scroll keys (1) to change the setting, then press the tabulator key (2) to go to the
next field (30). The setting of this field can now be modified using the scroll keys (1).
• Press the key ‘Prog’ (F1) to program the new value or the key ‘Canc’ (F3) to cancel the
modification operation (the original value will be retained).
• The procedure to modify other parameters is similar.
3.19 Programming compressor control modes
Control panel
Instruction book
38
API161475
Содержание GA 11 VSD
Страница 1: ...INSTRUCTION BOOK API161475 GA 11 VSD ...
Страница 2: ......
Страница 24: ...Menu flow for GA 5 up to GA 11 VSD simplified Instruction book 22 API161475 ...
Страница 55: ...Position of oil level sight glass Instruction book API161475 53 ...
Страница 83: ......