ETP TBP91-80-13
Safety Information
© Atlas Copco Industrial Technique AB - 9834 5051 00
3
Technical Data
Product Power Source
This product can be used with a battery or with an electrical
power cable with a power supply unit.
Product data
Motor voltage
36 V d.c.
Motor power
500 W
Speed range
800 - 6000 r/min
Torque range
40 - 80 Nm (29.5 - 59.0 ft lb)
Weight
1.8 kg (3.9 lb)
Battery Compatibility
Accessory
Article nr.
Battery, 36V (2.5Ah)
4211 6030 86
Charger Compatibility
Accessory
Article nr.
Flex charger
4211 6083 84
Ambient Temperature
Operating temperature, charge
+5 to +40 °C
(+41 to +104 °F)
Operating temperature, discharge
0 to +40 °C
(+32 to +104 °F)
Storage temperature
−20 to +40 °C
(−4 to +104 °F)
Wireless LAN Information
Regulatory Do-
main
Band
TxChannels
WORLD
2.4 GHz
1, 2, 3, 4, 5, 6, 7, 8,
9, 10, 11
U-NII-1
36, 40, 44, 48
U-NII-2
52, 56, 60, 64
U-NII-2e
100, 104, 108, 112,
116, 132, 136, 140
U-NII-3
-
ETSI
2.4 GHz
1, 2, 3, 4, 5, 6, 7, 8,
9, 10, 11, 12, 13
U-NII-1
36, 40, 44, 48
U-NII-2
52, 56, 60, 64
U-NII-2e
100, 104, 108, 112,
116, 120, 124, 128,
132, 136, 140
U-NII-3
149, 153, 157, 161,
165
FCC
2.4 GHz
1, 2, 3, 4, 5, 6, 7, 8,
9, 10, 11
U-NII-1
36, 40, 44, 48
U-NII-2
52, 56, 60, 64
U-NII-2e
100, 104, 108, 112,
116, 132, 136, 140
U-NII-3
149, 153, 157, 161,
165
Cable Power Supply Unit Compatibility
Accessory
Article nr.
Power Supply Unit 950
8432 0840 04
Maximum Radio Output Power
Radio Technology
Frequency Range
(MHz)
Maximum Trans-
mit Power EIRP
(dBm)
Wi-Fi®
2412-2472
19.1
Wi-Fi®
5180-5320
16.6
Wi-Fi®
5500-5700
17.3
Wi-Fi®
5745-5825
13.1
Bluetooth® wire-
less technology /
Bluetooth® Low
Energy
2402-2480
13.7
Wi-Fi® is a registered trademark of Wi-Fi Alliance®
The Bluetooth® word mark and logos are registered trade-
marks owned by Bluetooth SIG,Inc.
Charger Temperatures
Charger operating tempera-
ture
+5 to +40 °C
(+41 to +104 °F)
EU SAR value
EU SAR Value: 0.26
Declarations
Liability
Many events in the operating environment may affect the
tightening process and shall require a validation of results. In
compliance with applicable standards and/or regulations, we
hereby require you to check the installed torque and rota-
tional direction after any event that can influence the tighten-
ing result. Examples of such events include but are not lim-
ited to:
• initial installation of the tooling system
• change of part batch, bolt, screw batch, tool, software,
configuration or environment