7
PROGRAMMING INSTRUCTIONS – CAFÉ PLUS
The 3 and 4 lane machines are programmed in a very similar manner to the Café mini.
The main differences have been highlighted
.
The five buttons are named BEV 1, BEV 2, BEV 3, BEV 4, STOP.
.
BEV 1 and BEV 2 buttons does the same function as the COFFEE button to
increase/decrease time and toggle to enable or disable functions. BEV 3 is the
equivalent of the HOT WATER button in the 2 lane Café mini and is primarily for
saving and moving on to next mode.
.
IN the Café Plus, to get hot water or half cup, just press the STOP button once and
then the BEV button of your choice to get hot water/half cup of drink from that lane.
A longer press of the STOP button and you can enter the MENU mode and follow the
same instructions as the Café Mini programming.
.
NOTE THAT THE ATLANTIS MACHINES HAVE A LOT OF OTHER FEATURES
LIKE LANGUAGE CHANGE AND CALIBRATION WHICH CAN BE ENABLED
UNDER SUPERVISION OF AN AUTHORISED ENGINEER FROM THE COMPANY.
Press HALF and the screen would show CNTR RESET. Pressing TEA would show
YES. Then you have to enter the password and the counters of coffee and tea would
be reset to 0.
.
Press HALF again and we have the USER MESSAGE change option. Using the
COFFEE TEA and HALF buttons (for saving) you can actually change the name on the
display to your choice. A unique feature only on ATLANTIS machines.
Lastly pressing HALF would show CHANGE PASSWORD. Press TEA and the YES
option appears. Press HALF again and ENTER the old password followed by the new
password twice.
.
Press HALF again and the machine display shows “returns to the regular MAKE
YOUR CHOICE mode.
USER’S MANUAL
Next mode on pressing HALF is the SET DEFAULT option. In you enable the same
by imputing YES, then all settings of water, powder, temp etc would be restored to the
factory settings.
.
Press Half again and we now enter the SET FLUSH mode. Here we have the following
options (all available using the COFFEE/TEA switches). If we want to flush the machine
at regular intervals, specially when not in use, then we should enable – YES, this option.
We recommend this as well, because it not only cleans the water pathways, but also keeps
them warm. If you choose YES, then you can set the flush time interval to 10/ 30/60/90 mins
depending upon usage of the machine. If the machine is used extensively, then a higher
interval is recommended.
.
8
Specific fault message will be displayed when the m/c stops dispensing.
List of fault messages, their possible cause and remedial action are listed blow.
TROUBLESHOOT
1. Check heater fuse. If fuse has blown off, replace it.
2. Check loose connections continuity at heater/
fuse/holder/relay/terminals
3. Check loose connections at main PCB connector
and rectify.
4. Check 230 volt AC supply across heater terminal,
if power supply not detected replace heater.
5. If power supply not detected, check DC signal
across relay terminals.
a.) If power supply not detected replace relay.
b.) If power supply not detected, then replace PCB.
1. If display show “Heating....”
for more than 10 minutes
2. If display shows
“Water tank empty”
3. Overheating in boiler tank
HOT BEVERAGE DISPENSER
1. Check water level in bottle top
2. Check continuity of sensor wire from PCB to tank
1. check loose connection of temperature sensor on
the boiler.
2. Check DC signal across heater relay terminal
a) If power supply not detected, replace repay.
b) if power supply not detected, replace
temperature sensor.
4. Electric shock
5. As soon as machine is
switched on power supply
trips.
1. Check earthing / polarity in supply socket.
2. Check water leaking inside the machine and
rectify it.
3. Ch loose connection of earthing wire with
machine body.
4. check continuity between machine body & earth
pin on 15 Amp power plug. if continuity is not there
replace power cord
1. Check correct rating of MCB.
2. Remove 15 Amp fuse & switch on. If it is tripping
again, reconnect the same & if it not tripping,
replace heater.