32
Installation of the Atlantis Solar Air Conditioner
2. Indoor Unit Installation
1) As shown in the following picture, pipelines are connected in five directions with the
indoor unit. When the pipelines are connected in
③
or
④
direction, please adopt the
saw to open a preformed groove on the panel. When the pipelines are connected in
⑤
direction, please adopt the saw to open a preformed groove under the panel.
2) Adopt five 5Y51 size wooden bolts to fix the board on the wall
Notice:
*
If indoor unit is installed on the concrete wall, please adopt bulgy bolt.
*
When you install the board, you are supposed to use weight dropper to test the board
whether it is horizontal or vertical.
*
The installed board should be able to bear 50 kg.
*
Ensure that the board is firm and solid.
3) Based on the junction direction of the pipeline (Please consult the following picture), a
hole which is provided with the diameter of 65 mm, is drilled in the corresponding place on
the wall. Then the wall bushing and the tube cap are placed into the hole. If the pipeline is
①
Back
③
Left
⑤
down
②
Left-back
④
Right
Weight dropper
Plumb-line
Marked line
Wooden bolt
The board