background image

                                                                                                    

50-Port Dual Web Rack Switch

 

 

 
Copyright

 

The Atlantis Land logo is a registered trademark of Atlantis Land SpA. All other names mentioned 
mat be trademarks or registered trademarks of their respective owners. Subject to change without 
notice. No liability for technical errors and/or omissions.

 

 

 

CE Mark Warning

 

This is a Class A product. In a domestic environment, this product may cause radio interference, in 
which case the user may be required to take adequate measures. 
 
 

FCC Warning

 

This equipment has been tested and found to comply with the regulations for a Class A digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference when the equipment is operated in a commercial environment. This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with this user’s guide, may cause harmful interference to radio communications. Operation 
of this equipment in a residential area is likely to cause harmful interference, in which case the user 
will be required to correct the interference at his own expense. 
 

UL Warning

 

a) Elevated Operating Ambient Temperature- If installed in a closed or multi-unit rack assembly, the 
operating ambient temperature of the rack environment may be greater than room ambient.  Therefore, 
consideration should be given to installing the equipment in an environment compatible with the 
manufacturer's maximum rated ambient temperature (Tmra). 
 b) Reduced Air Flow- Installation of the equipment in a rack should be such that the amount of air 
flow required for safe operation of the equipment is not compromised. 
 c) Mechanical Loading- mounting of the equipment in the rack should be such that a hazardous 
condition is not achieved due to uneven mechanical loading. 
 d) Circuit Overloading- Consideration should be given to the connection of the equipment to the 
supply circuit and the effect that overloading of circuits might have on over current protection and 
supply wiring.  Appropriate consideration of equipment nameplate ratings should be used when 
addressing this concern. 
e) Reliable Earthing- Reliable earthing of rack-mounted equipment should be maintained.  Particular 
attention should be given to supply connections other than direct connections to the branch circuit 
(e.g., use of power strips).

 

 
 
 
 
 
 
 

 

 
 
 
 
 

Содержание A02-F48-4G

Страница 1: ...50 Port Dual Web Rack Switch A02 F48 4G USER S MANUAL A02 F48 4G_ME01...

Страница 2: ......

Страница 3: ...will be required to correct the interference at his own expense UL Warning a Elevated Operating Ambient Temperature If installed in a closed or multi unit rack assembly the operating ambient temperatu...

Страница 4: ...ING 4 2 4 CONNECTING NETWORK CABLE 5 2 5 AC POWER 6 2 6 IDENTIFYING EXTERNAL COMPONENTS 6 Front Panel 6 Rear Panel 7 Understanding LED Indicators 7 CHAPTER 3 9 3 1 INSTALLING THE WEB MANAGEMENT UTILIT...

Страница 5: ...Port Dual Web Rack Switch iii Reset Settings 23 Logout 23 APPENDIX A 24 RJ 45 PIN SPECIFICATION 24 APPENDIX B 25 TECHNICAL SPECIFICATIONS 25 APPENDIX C 26 SUPPORT 26 A02 F48 4G _ME01 December 2004 V1...

Страница 6: ......

Страница 7: ...ncrease in theoretical throughput over 100 Mbps Fast Ethernet and a hundredfold increase over 10 Mbps Ethernet Since it is compatible with all 10 Mbps and 100 Mbps Ethernet environments Gigabit Ethern...

Страница 8: ...level of the Ethernet protocol transmitting among connected Ethernet or Fast Ethernet LAN segments Switching is a cost effective way of increasing the total network capacity available to users on a lo...

Страница 9: ...es or an up link port Full half duplex transfer mode for 10 100Mbps RJ45 port Full duplex transfer mode for Gigabit port Wire speed reception and transmission Store and Forward switching scheme capabi...

Страница 10: ...y cool and dry place See Technical Specifications for the acceptable temperature and humidity operating ranges Install the Switch in a site free from strong electromagnetic field generators such as mo...

Страница 11: ...e The Switch also supports 2 Ports 1000Mbps Gigabit Ethernet that runs in Auto negotiation mode and 10Mbps Ethernet or 100Mbps Fast Ethernet that runs both in half and full duplex mode and 1000Mbps Gi...

Страница 12: ...cators chapter below Fast Ethernet Ports Port 1 48 These ports support network speeds of either 10Mbps or 100Mbps and can operate in half and full duplex transfer modes These ports also supports autom...

Страница 13: ...t button is to reset all the setting back to the factory default Note Be sure that you recorded the setting of your device else all the setting will be erased when pressing the Reset button Rear Panel...

Страница 14: ...port is successfully connected to an Ethernet network Blinking When the Link ACT LED is blinking the port is transmitting or receiving data on the Ethernet network Off No link SPEED On Green When the...

Страница 15: ...ng you through the installations of the Web Management utility 1 Insert the Utility CD in the CD Rom Drive 2 From the Start menu on the Windows desktop choose Run 3 In the Run dialog box type CDRom Dr...

Страница 16: ...he Discovery List to the Monitor List System word definitions in the Discovery List MAC Address Shows the device MAC Address IP Address Shows the current IP address of the device Protocol version Show...

Страница 17: ...ed Trap IP Shows the IP where the Trap to be sent Subnet Mask Shows the Subnet Mask set of the device Gateway Shows the Gateway set of the device View Trap The Trap function can receive the events tha...

Страница 18: ...ress Subnet Mask Gateway Set Trap to Trap IP Address System name and Location Select the device in the Discovery list or Monitor List and press this button then the Configuration Setting window will p...

Страница 19: ...you open the Web Management Utility next time it will auto load the default recorded setting Monitor Save As To record the setting of the Monitor List in appointed filename and file path Monitor Load...

Страница 20: ...nnection make sure the manager PC must be set on same the IP network For example when the default network address of the default IP address of the Web Smart Switch is 192 168 0 1 then the manager PC s...

Страница 21: ...ettings VLAN Settings Trunk Setting Port Settings In Port Settings menu this page will show each port s status press the ID parameter to set each port s Speed Flow Control and QoS priority When you ne...

Страница 22: ...alf 10M Full 10M Half Auto and Disable Flow Control This setting determines whether or not the Switch will be handling flow control Set FlowCtrl to Enable for avoiding data transfer overflow Or it set...

Страница 23: ...sn t work In the same way port 25 s QoS doesn t work when we send packet to port 2 VLAN Settings Virtual Local Area Network Group individual ports into a small Virtual network of their own to be indep...

Страница 24: ...an Trunk Setting The Trunk function enables to cascade two devices with a double times bandwidth up to 4000Mbps in full duplex mode There are seven groups for trunk setting each group has fixed settin...

Страница 25: ...tus on this screen it will show the System Status Port Status VLAN Status and Trunk Status Press Refresh when you need to renew the posted information Statistics The Statistic Menu screen will show th...

Страница 26: ...anagement Utility you can easily recognize the device by using the System Name and the Location Name The Login Timeout is to set the idle time out for security issue when there is no action when runni...

Страница 27: ...en there is using a wrong password login and it will record from where the IP to be login Fiber Port Events Monitoring the Fiber port status Link Up Link Down a trap when there is linking status happe...

Страница 28: ...assword press the Reset button in the rear panel of the Switch the current setting includes VLAN Port Setting etc will be lost and the Switch will restore to the default setting Backup Setting The bac...

Страница 29: ...the factory Be aware that the entire configuration will be reset the IP address of the device will be set to default setting 192 168 0 1 password admin Logout When press this function the web configur...

Страница 30: ...tables show the standard RJ 45 receptacle connector and their pin RJ 45 Connector pin assignment Contact Media Direct Interface Signal 1 TX tx 2 TX tx 3 Rx rx 4 Not used 5 Not used 6 Rx rx 7 Not used...

Страница 31: ...UTP Cat 5 up to 100m Fiber module mini GBIC Fiber module 1000BBASE SX LX Number of Ports 48 10 100Mbps Auto MDIX RJ45 ports 2 10 100 1000Mbps Auto MDIX RJ45 ports 2 mini GBIC fiber slot AC inputs 100...

Страница 32: ...tact the dealer where you bought this Switch If you have any other questions you can contact the Atlantis Land company directly at the following address Atlantis Land SpA Viale De Gasperi 122 20017 Ma...

Отзывы: