Edition: 02 / 2015
Page 45 / 56
VARMAX TWIN -
Installation, Use and Maintenance
VX210 diagram only:
• Domestic hot water
menu
Confi
gure an Anti-Legionnaires' Disease
function
Anti-Legionnaires' Disease function
(1640)
- - -
Periodic Anti-Legionnaires' Disease
function (1641)
- - -
Day week Anti-Legionnaires' Disease function (1642)
- - -
Anti-Legionnaires' Disease setting temperature (1645)
- - -
Anti-Legionnaires' Disease function duration (1646)
- - -
VARMAX TWIN optimisation:
The Varmax Twin may be optimised as necessary using the parameters in the
Flow
menu. Refer to
the NAVISTEM B3000 boiler's controller manual for more details.
Diagrams: VX210 / VX220
page 8 / 8
Maintenance optimisation
A maintenance message may be generated that does not set the generator to fault. This maintenance
message may be displayed after the following 3 counters have expired:
• Time since last maintenance (or commissioning): set parameter 7044 to 12 months
(
Maintenance / Special regime
menu)
• Burner's operating hours (parameter 7040 - menu
Maintenance / Special regime
menu)
• Number of starts (parameter 7042 - menu
Maintenance / Special regime
menu)
These last 2 parameters are dependent on the boiler's hydraulic installation. We recommend
using at least parameter 7044 for annual maintenance.
Adjust the DHW release mode
DHW release (1620)
Timer program 4/
DHW
Line No.
Value
• Timer programme 4/DHW
menu
Preselection
Preselection (560)
- - -
Adjust the timer programming
On / off phases (561...566)
- - -
• DHW tank
menu
Adjust the over value
Output setting temperature over value (5020)
- - -