21
Parameters
1/ Setting the thermostat
Turn the knob to
Stop
and press the right button down for 5 seconds until
H200 vx:xx is displayed (maintenance menu only to be used by the installer).
Press
OK
.
CF01
appears on the screen.
CF01 - Correction of the ambient temperature measurement
If there is a difference between the actual temperature in the room (thermometer)
and the temperature measured and displayed by the device, this menu can be used
to change the probe's measurement to compensate for this difference (from -4°C to
+4°C in 0.1°C steps).
Adjust the setting with
+
or
-
, then press
OK
to confirm and move onto the next
menu.
CF02 - Temperature display in AUTO mode
Adjust the setting with
+
or
-
, then press
OK
to confirm and move onto the next
menu.
CF03 - Not Used
Press
OK
to move onto the next menu.
5 sec.
Instruction permanent display
Displayedtemperature
Real room
temperature
GB