12
-
An Earth connection is prohibited. Do not connect the pilot
wire (black wire) to Earth.
- The installation must be fitted with an all-pole cut-off switch with a
contact opening distance of at least 3mm.
- If the power cable is damaged, it must only be replaced by an electrician.
- If you are using the pilot wire and it is protected by a 30mA differential
(
e.g.: bathroom use
), the pilot wire’s power supply must also be pro-
tected on this differential.
Wiring diagram for the heating panel
- Cut off the power supply and connect the wires as shown in the fol-
lowing diagram:
COMFORT
ECO
FROST
SWITCH-OFF
OF HEATING
AND POWER
CUT-OFF
SIGNAL TO BE
TRANSMITTED
MEASUREMENT BET-
WEEN THE PILOT WIRE
AND NEUTRAL
0 Volt
230 Volt
-115 Volts néga-
tive
+115 Volts
positive
- You can connect the pilot wire if your home is equipped with a pro-
gramming unit or controller.
In this case, make the following checks according the selected mode
(
Comfort, Eco, etc.
) to that the programming instructions are being
transmitted correctly:
Содержание SOLIUS
Страница 30: ...30 ...
Страница 31: ...31 2 5 обслуживание RU ...
Страница 32: ...32 ...
Страница 33: ...33 RU ...
Страница 34: ...34 ...
Страница 36: ...36 6 1 2 3 4 5 8 7 ...
Страница 37: ...37 11 9 12 10 CZ ...
Страница 38: ...38 13 15 14 16 ...
Страница 39: ...39 CZ ...
Страница 40: ...40 RSGHEP10 12 80 0050 G Avril 15 ...