• In case of excessive vibration, unusual noise or odor, turn off the power immediately and
consult your nearest dealer.
Maintenance and Inspection
• Regular maintenance and inspections are a necessity for continued efficient functioning. If
any abnormal conditions are noticed, refer to the section on Troubleshooting and take
corrective measures immediately.
Monthly Inspection / Cleaning
• Check for any drop in performance. Reduced performance is usually caused by debris
blocking the pump intake.
• Detach the power cable from the receptacle or turn off the power supply (circuit breaker).
• Disconnect the pump discharge and remove the pump from the water.
• Remove any accumulated debris from the surface of the pump and pre-filter.
• Remove the pre-filter, inspect the adjustable flow and remove any accumulated debris.
• Remove the threaded inlet cover by rotating it in a counterclockwise half turn while pulling
lightly outward from the pump body.
• Inspect the impeller and remove any debris that may be present.
• Spin the impeller. If the impeller is difficult to turn, feels “gritty”, or a grinding noise is
evident in the rotor chamber, remove the rotor as per the instructions below.
Removing the Rotor
• Remove the impeller assembly by pulling outward from the rotor chamber.
Note:
The impeller assembly is comprised of six individual parts shown in the image below.
Take care not to lose or misplace any of these pieces during the cleaning process.
Friction
Washer
Friction
Washer
Ceramic Shaft
Impeller/
Magnetic Rotor
Pre-filter
Threaded
Inlet Cover
Impeller
Assembly
Rotor
Chamber
Pump Body/Motor
Flow Adjustor
Rubber Feet
Rubber
Bushing
Rubber