System status
The "
Active Functions
" page tells you which services are operating and allows you to
change their status.
-"
Indoor comfort
":
Heating / Cooling / Stop.
-
"Area 1" / "Area 2" / "Hot water"
:
ON / Stop.
If "Indoor Comfort" is set to "Stop", Area 1 and 2 cannot be modified.
Active functions
Area 1
Start
Indoor comfort
Heating
Start
Area 2
Start
Stop
Hot water
Emergency mode
The "
Control Panel
" allows you to see the status of the different functions and actuators.
1
- Press the knob to access the "
Control Panel
" second screen.
3
- Press the knob to return to the "
System Status
" menu.
1
Control panel
Next
Generator
40%
Return T°
50°C
Mode
Heating
Elec. backup
Stop
HP circulation pump
ON
Flow setpoint
26°C
HP flow T°
60°C
Outdoor T°
20°C
2
Control panel
Next
Setpoint T°
20°C
Area 1
Flow T° setpoint
26°C
Circulation pump
ON
3
Control panel
Next
Setpoint T°
20°C
Area 2
Flow T° setpoint
26°C
Flow T°
22°C
Circulation pump
ON
Valve
Open
4
Control panel
Next
Setpoint T° DHW
55°C
DHW
Hot Water T°
52°C
Valve
Circuit
Backup
ON
5
Control panel
Complete
Power shedding input
Inactive
Smartgrid EX2
Active
External fault input
Inactive
10
:
Outside
sensor,
32
: Flow sensor 2,
33
: Flow sensor HP,
44
: Return sensor HP,
50
: DHW sensor 1,
60
: Room sensor 1,
65
: Room sensor 2,
83
: BSB short-circuit,
127
: Legionella temp,
212
: Internal comm failure,
356
: Flowmeter,
369
: External,
370
: Thermodynamic source,
441
: BX31 no function,
442
: BX24 no function,
443
: BX33 no function,
444
: BX34 no function,
516
: Heat pump missing.
For more info about errors
"
Fault Diagnosis", page 76.
Errors history
Error
10/09/2016
441
Error
10/09/2016
369
Error
09/09/2016
441
Error
09/09/2016
369
Error
20/08/2016
369
Error
20/08/2016
369
Error
01/08/2016
441
Error
01/08/2016
369
Error
14/07/2016
441
Error
06/05/2016
441
Some settings (or menus) might not be displayed. They are dependent on the installation's configuration (and installed options).
System status
Active functions
Control panel
Errors history
- 60 -
alfea Excellia HP A.I. / Installation / 1944 - FR