Type of use
":
Power sh Off-peak hours / Smartgrid.
"
EX1: function activation
":
230V / 0V.
"
EX2: function activation
":
230V / 0V.
Heat Pump
Tariff input configuration
EX1: function activation
230V
EX2: function activation
0V
Type of use
Power sh
Off-peak hours
▼
Electrical back-up
"
Authorisation if outd. T° <
":
-50°C... 50°C.
"
Switching setting
":
0°Cmin... 500°Cmin.
Configuration
Back-up
Switching setting
100°C min
Authorisation if outd. T° <
2°C
Some settings (or menus) might not be displayed. They are dependent on the installation's configuration (and installed options).
1
- "
Authorisation if outd. T°<
" :
--- , -15°C... 10°C.
"
Authorisation if outd. T°>
" : 0°C... 30°C.
"
Switching setting
" : 10°C.min... 500°C.min.
2
- "
Minimum shutdown time
" : ---, 1min... 120min.
"
Post-circulation
" : 0min... 120min.
"
DHW operating
" :
Emergency / Back-up / Priority.
1
Configuration
Connection boiler
Switching setting
Next
100°C.min
Authorisation if outd. T°<
Authorisation if outd. T°>
2°C
---°C
2
Configuration
Connection boiler
DHW operating
Complete
Emergency
Minimum shutdown time
Post-circulation
---
20min
HP configuration
HP configuration
HP configuration
HP
Tariff input configuration
Electrical back-up
Connection boiler
- 59 -
alfea Excellia HP A.I. / Installation / 1944 - FR