Atlantic Ultraviolet Sanidyne PREMIUM Скачать руководство пользователя страница 3

3

SAFETY INSTRUCTIONS

  To guard against injury, basic safety precautions should be observed, including the following:

1. 

Read and follow 

ALL

 safety instructions.

2.   

 

  Avoid exposure to direct or reflected germicidal ultraviolet rays. Germicidal 

ultraviolet rays are 

harmful 

to the eyes and skin.

3.  Intended for indoor use only.
4.  Do not alter design or construction.
5.  Do not use this sanitizer for other than its intended purpose, as described in this manual.
6.  Do not use this sanitizer in occupied areas. The supplied “

DANGER - DO NOT ENTER…

” sign(s) 

MUST

 be clearly    

displayed to warn against entering the area during the disinfection cycle without proper personal protection equipment.

7. 

Germicidal ultraviolet rays may break down plastic, rubber or other non-metallic materials, with 

inadequate resistance to ultraviolet. Shield all plastic, rubber or other non-metallic parts which may be exposed to direct or 

reflected germicidal ultraviolet rays.

8.  Do not remove any labels.
9. 

 

  Do not operate without proper electrical ground.

10. 

Do not operate the sanitizer if the power cord and/or plug are damaged, or if any other damage to the sanitizer is 

 

visible or suspected.

11. 

Utility power supplied to the sanitizer, 

MUST

 match power requirements listed on the sanitizer label.

12. 

 

  

Always disconnect power to the fixture before performing any service or maintenance

.

13. 

Read and follow all notices and warnings on the sanitizer.

14. 

SAVE THESE INSTRUCTIONS.

SAFETY WARNINGS

•  All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit.
• 

The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to 

observe precautions could result in injury to people or damage to property.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards.  

Obey all safety messages that follow this symbol to avoid possible injury or death. 

 

This symbol is used to identify the need to wear

 

protective gloves.

Caution indicates a 

POTENTIALLY

 

hazardous situation, which, if not avoided, 

MAY

 result in minor or moderate injury.

Caution used without the safety alert symbol 

indicates a potentially hazardous situation, which, 

if not avoided, may result in property damage.

Warning indicates a 

POTENTIALLY

  

hazardous situation, which, if not avoided, 

COULD

 result in death or serious injury.

This symbol is used to identify an 

ULTRAVIOLET LIGHT

 hazard.

This symbol is used to identify an 

ELECTRICAL 

SHOCK

 or 

ELECTROCUTION

 hazard.

This symbol is used to identify the need to wear 

approved ultraviolet blocking eyewear.

This symbol is used to identify the need to wear approved 

ultraviolet blocking face shield.

This symbol is used to identify components which must 

not be disposed of in trash

Danger indicates an

 IMMINENTLY  

hazardous situation, which, if not avoided, 

 

WILL

 result in death or serious injury.

Содержание Sanidyne PREMIUM

Страница 1: ...ctions Save These Instructions UV Ultraviolet Radiation Protect eyes and skin from direct and reflected radiation DANGER Manufacturers Engineers Sales Service Germicidal Ultraviolet Equipment Lamps 37...

Страница 2: ...16 MAINTENANCE LOG 17 19 USER ASSISTANCE 20 Patent Notice 20 WARRANTY PRODUCT REGISTRATION 20 These instructions generally describe the installation operation and maintenance of the Sanidyne Premium...

Страница 3: ...3 Read and follow all notices and warnings on the sanitizer 14 SAVE THESE INSTRUCTIONS SAFETY WARNINGS All personnel should be alerted to the potential hazards indicated by the product safety labeling...

Страница 4: ...or process No warranty or representation is made by the manufacturer with respect to suitability or performance of this equipment or to the results that may be expected from its use The user should p...

Страница 5: ...le of Operation The Sanidyne Premium design has been carefully conceived to provide direct germicidal ultraviolet exposure for air and surface disinfection in unoccupied areas to disinfect and prevent...

Страница 6: ...nspect all packing materials to prevent the loss of accessories spare parts or instructions Do not discard packing materials until Sanidyne Premium is assembled checked and confirmed The Sanidyne Prem...

Страница 7: ...tart Stop Button Begins treatment time countdown also used to restart unit after an intruder is sensed in Operating Area 5 Power Indicator Glows RED when power is applied to unit and will flash during...

Страница 8: ...te and 30 seconds to exit area b The words LEAVE AREA appear on the lower status bar c Alarm on unit begins to sound d The word PrEP flashes on the Keypad during the Countdown Time when Treatment Time...

Страница 9: ...ler 13 ON OFF Button Turns the power to the device on or off and can be used to restart the device To turn on the device this button must be pushed in and held for 2 seconds If the device is on the Ho...

Страница 10: ...ment operation will take place It is the users responsibility to post signs or notices for all personnel and persons in the building or facility so that they be made aware that the Operation Area is o...

Страница 11: ...than 30 seconds remain on the countdown time the Sanidyne Premium will automatically reset giving 30 seconds more to leave the Operation Area Occupancy Sensors do not protect the entire Operation Area...

Страница 12: ...n the display or at the Sanidyne Premiumby pressing the START STOP on the Keypad If the Alarm is turned off at the Sanidyne Premiumthe operator can reset the fixture by pressing the START STOP button...

Страница 13: ...r table etc 2 Measure the longest distance from the Sanidyne Premium to the farthest wall Use this length to compare to the Distance From Fixtures Time Minutes shown on Figure 5 below 3 For example if...

Страница 14: ...D AN ULTRAVIOLET BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN NOTE STER L RAY lamps used in the Sanidyne Premium have ArmorLiteTM Safety Shield which is a protective co...

Страница 15: ...Surelite Ballast not operating Disconnect the fixture from utility power then replace ballast Sanidyne Premium fails to shut off Microprocessor assembly faulty Wearing protective clothing and face shi...

Страница 16: ...side and can be placed in supplied wall holder Uses 1 AAA battery 6 UV C Dosimeter Card 00 0373 Contains a patented colorimetric indicator that changes color at 25 50 and 100 mJ cm2 to visibly confirm...

Страница 17: ...17 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Страница 18: ...18 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Страница 19: ...19 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Страница 20: ...including warranties of merchantability and fitness for a particular purpose whether or not purposes or specifications are described herein We further disclaim any responsibility whatsoever to the cus...