![Atlantic Ultraviolet Sanidyne PREMIUM Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/atlantic-ultraviolet/sanidyne-premium/sanidyne-premium_owners-manual_3000436015.webp)
15
TROUBLESHOOTING
Always disconnect power to the
fixture before performing any service or maintenance
.
IN ORDER TO PERFORM THIS TASK, WEAR PERSONAL PROTECTION EQUIPMENT; GLOVES,
LONG SLEEVE SHIRT WITH NO GAPS BETWEEN CUFFS AND GLOVES, AND AN ULTRAVIOLET
BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN.
IMPORTANT:
This fixture is to be serviced
ONLY
by qualified and factory authorized personnel.
Table 1 – Troubleshooting
Problem
Possible Cause
Corrective Action
Sanidyne
®
Premium
not operating
Power disconnected
Check connections.
Fuse not operating
Remove power connector to check and
replace fuse if necessary.
Lamp not operating
STER-L-RAY
®
Germicidal lamp faulty
Swap suspect lamp, with lamp known to be good.
If suspect lamp does not operate, replace lamp.
STER-L-RAY
®
Germicidal
lamp not properly seated
Check lamp socket and re-install lamp if necessary.
Loose Connection
Inspect for loose or disconnected wires.
Surelite
™
Ballast not operating
Disconnect the fixture from utility power; then replace ballast.
Sanidyne
®
Premium
fails to shut off
Microprocessor
assembly faulty
Wearing protective clothing and face shield, enter area, and
disconnect power to unit. Call factory for technical service.
Cooling fan
not operating
Fan failure
Check fan connections and replace if it does not operate.
Low air flow through
cooling fans
Fan filter clogged
Remove filter and clean. Replace if filter appears worn or old.
TECHNICAL SPECIFICATIONS
Table 2 – Technical Specifications
Model:
40-5240C
Voltage: (v)
120v
Amperage: (A)
16A
Hertz: (Hz)
50/60 Hz.
Maximum Treatment Time: (Hours)
24 Hours
Weight: (Pounds)
76 lbs.
Dimensions:
Length: (Inches)
21-3/4″
Width: (Inches)
20-15/16″
Height: (Inches)
68-1/2″
Lamp Data:
Lamp Model:
05-0250
Number of Lamps:
8
Power Consumption:
(Watts per Lamp)
176W
Ultraviolet Output:
(Watts per Lamp)
60 UV Watts
Average Effective Life: (Hours)
13,000 Hours
Wattage is lamp watts only and does not include ballast loss.
Ultraviolet output at 254nm at 100 hours and 80 °F (approximate).
All specifications, dimensional data, etc are approximate and subject to change without notice.