Atlantic Ultraviolet Sanidyne PREMIUM Скачать руководство пользователя страница 16

16

OPTIONAL ACCESSORIES 

1. 

Zenith

TM

 Germicidal Ultraviolet Detector (30-1015):

 A sensitive, hand-held, self-contained battery operated ultraviolet 

meter that can be used for:
•  Monitoring UV-C Germicidal Lamp Intensity & Aging

• 

Measuring UV-C Germicidal Fixture Leakage.

2. 

Promate

 

Safety Glasses (00-1299): 

Safety eyewear 

MUST

 be used as general-purpose safety protection and for 

additional shielding from ultraviolet rays.

3. 

Additional 

Promate

 

Face Shields (00-0126):

 Lightweight visor with adjustable headgear provides eye and face 

protection from ultraviolet rays. 

Two (2) face shields are included with purchase of 

Sanidyne

®

 

Premium

 but additional 

face shields may be purchased.

4. 

Additional 

Promate

 

Danger Signs (98-1827): 

Glossy card stock signs (8-1/2″ x 11″) to be affixed to entry door(s) to 

warn that an ultraviolet sanitizer is in use and that the treatment area 

MUST

 not be entered. 

Sanidyne

®

 is for use only 

in 

unoccupied

 areas. Four (4) warning signs are included with purchase of 

Sanidyne

®

 

Plus

 but additional signs may be 

purchased. 

NOTE:

 Danger Signs have English on one side and Spanish on the other.

5. 

Assure

 UV-C Dosimeter (00-0376):

 A portable, full-featured instrument that provides highly-accurate UV-C 

measurements in mJ/cm

2

. Sits upright, on back or side, and can be placed in supplied wall holder. Uses 1 AAA battery.

6. 

UV-C Dosimeter Card (00-0373):

 Contains a patented colorimetric indicator that changes color at 25, 50, and 100 mJ/cm

2

 to 

visibly confirm that your 

Sanidyne

®

 

Premium 

is achieving the desired UV-C exposure. Each card is designed for one (1) 

treatment cycle and 

CANNOT

 be reused. Complete instructions for use are on back of card. One (1) card has been included 

with this purchase but additional cards may be purchased by phone or on BuyUltraviolet.com.

7. 

Personal UV-C Exposure Indicators (00-0375):

 These indicators change color to reveal the word “STOP” if personnel are 

exposed to an accumulated dose of 6 mJ/cm

2

 of UV-C irradiation. Adhesive backing sticks to clothing. Available in packs of 

10. Designed for single, daily use and 

CANNOT

 be reused.

For more information and purchasing contact our offices, weekdays between 8:30 am and 5:00 pm Eastern time, at:

 

Atlantic Ultraviolet Corporation

®

, 375 Marcus Boulevard, Hauppauge, New York, 11788 

 

Tel: (631) 273-0500 • Fax: (631) 273-0771 • Email: [email protected] • Website: Ultraviolet.com – BuyUltraviolet.com

REPLACEMENT PARTS 

Table 3 – Replacement Parts

Item No.

Description

Part No.

1

STER-L-RAY

®

 

Germicidal Lamp

05-0250

2

Surelite

™ 

Ballast

10-0255

3

Cooling Fan Guard with Filter

40-1467

4

Line Cord : 10ft, 20A, 120v

35-2122

5

Fuse: 250v 20A

35-2123

Other replacement parts are available. Consult Atlantic Ultraviolet Corporation

®

 for specific requirements.

Содержание Sanidyne PREMIUM

Страница 1: ...ctions Save These Instructions UV Ultraviolet Radiation Protect eyes and skin from direct and reflected radiation DANGER Manufacturers Engineers Sales Service Germicidal Ultraviolet Equipment Lamps 37...

Страница 2: ...16 MAINTENANCE LOG 17 19 USER ASSISTANCE 20 Patent Notice 20 WARRANTY PRODUCT REGISTRATION 20 These instructions generally describe the installation operation and maintenance of the Sanidyne Premium...

Страница 3: ...3 Read and follow all notices and warnings on the sanitizer 14 SAVE THESE INSTRUCTIONS SAFETY WARNINGS All personnel should be alerted to the potential hazards indicated by the product safety labeling...

Страница 4: ...or process No warranty or representation is made by the manufacturer with respect to suitability or performance of this equipment or to the results that may be expected from its use The user should p...

Страница 5: ...le of Operation The Sanidyne Premium design has been carefully conceived to provide direct germicidal ultraviolet exposure for air and surface disinfection in unoccupied areas to disinfect and prevent...

Страница 6: ...nspect all packing materials to prevent the loss of accessories spare parts or instructions Do not discard packing materials until Sanidyne Premium is assembled checked and confirmed The Sanidyne Prem...

Страница 7: ...tart Stop Button Begins treatment time countdown also used to restart unit after an intruder is sensed in Operating Area 5 Power Indicator Glows RED when power is applied to unit and will flash during...

Страница 8: ...te and 30 seconds to exit area b The words LEAVE AREA appear on the lower status bar c Alarm on unit begins to sound d The word PrEP flashes on the Keypad during the Countdown Time when Treatment Time...

Страница 9: ...ler 13 ON OFF Button Turns the power to the device on or off and can be used to restart the device To turn on the device this button must be pushed in and held for 2 seconds If the device is on the Ho...

Страница 10: ...ment operation will take place It is the users responsibility to post signs or notices for all personnel and persons in the building or facility so that they be made aware that the Operation Area is o...

Страница 11: ...than 30 seconds remain on the countdown time the Sanidyne Premium will automatically reset giving 30 seconds more to leave the Operation Area Occupancy Sensors do not protect the entire Operation Area...

Страница 12: ...n the display or at the Sanidyne Premiumby pressing the START STOP on the Keypad If the Alarm is turned off at the Sanidyne Premiumthe operator can reset the fixture by pressing the START STOP button...

Страница 13: ...r table etc 2 Measure the longest distance from the Sanidyne Premium to the farthest wall Use this length to compare to the Distance From Fixtures Time Minutes shown on Figure 5 below 3 For example if...

Страница 14: ...D AN ULTRAVIOLET BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN NOTE STER L RAY lamps used in the Sanidyne Premium have ArmorLiteTM Safety Shield which is a protective co...

Страница 15: ...Surelite Ballast not operating Disconnect the fixture from utility power then replace ballast Sanidyne Premium fails to shut off Microprocessor assembly faulty Wearing protective clothing and face shi...

Страница 16: ...side and can be placed in supplied wall holder Uses 1 AAA battery 6 UV C Dosimeter Card 00 0373 Contains a patented colorimetric indicator that changes color at 25 50 and 100 mJ cm2 to visibly confirm...

Страница 17: ...17 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Страница 18: ...18 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Страница 19: ...19 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Страница 20: ...including warranties of merchantability and fitness for a particular purpose whether or not purposes or specifications are described herein We further disclaim any responsibility whatsoever to the cus...