![ATLANTEK 200 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/atlantek/200/200_operators-manual_2999673014.webp)
SAMPLE OF THE TEST MENU
TEST MENU
Head Type: Rohm2
File Name: TEST1
Printhead Set Temperature: 35
Image Width: Full
Choose from: current values
F1 - Reset to default values
F2 - Pattern type 50%
F3 - Dot pulse Duration (Ton) Seq up to 0.50 msec
F4 - Cycle Time (Tcycle) 5.0 ms
F5 - Media Type ATL-693
F6 - Head Heating(ON/OFF) ON
F7 - Wait for Temperature NO
F8 - Configure Output Image
F9 - Do the Above Defined Test
F10 - Exit to Main Menu - caution choices will not be saved
USING FUNCTION KEYS
Choosing F2,F3,F4,F6 or F8 results in a request to input an appropriate value and a return to
the TEST EDITOR MENU.
Parameter sequencing may be selected for choices F2,F3, or F4. This choice produces ten
samples down the page with the first sample printed at 10% of the final value, the second at
20% and so on down the page. Sequencing of a test pattern is only available when the
Checker board pattern is selected.
Changing the desired Test pattern is done by selecting the F2 option and choosing one of the
supported test patterns from the displayed Menu.
Selecting the F8 option (Configure Output Image) from the TEST MENU will allow an
operator to alter the image header width or change the test patterns image width.
NOTE: The following conditions automatically invoke the REDUCED printing mode.
- Pattern Sequence tests
- Hi Speed TCYCLE Sequence
- Any test session where the defined TCYCLE value is less than 2.0 msec.
Also, due to differences in the construction of thermal printheads for various manufactures,
the width of the REDUCED print area is not the same for all printheads.
For Example:
Reduced print width
Kyocera KST-216-8MPD1
4 inches
Rohm KF-2008-B1
2.66 inches