TEST CONTROLLER FRONT PANEL CONTROLS
There are four controls on the front panel of the test controller.
Each is described as follows:
1. RESET - Performs a microprocessor hardware reset. This button is used to perform
re-synchronization of the test controller and the computer.
2. TEST - Prints a test pattern.(providing that the printhead voltage is within
printing limits and the printhead is in the down position.)
3. FEED - Feed advances the paper to the beginning of the next page.
4. VOLT ADJ. - Allows the adjustment of voltage applied to the printhead. The applied
voltage is displayed on the panel meter on the front of the printer as well
as on the upper right corner of the CRT.
****CAUTION****
******************************************************************
Be sure to keep the voltage applied to the printhead below the manufacturers
maximum rated voltage or printhead damage may result.
******************************************************************
CHANGING PRINTHEADS
Tools necessary: 1/8" Allen wrench, 9/16" thin open end wrench (approx. .1" thick)
Each printhead is supplied mounted on its own unique carrier plate which maintains proper dot
line alignment. The carrier plates should remain attached to the printhead.
*****************
****IMPORTANT****
*****************
******************************************************************
NEVER ATTEMPT PRINTHEAD REPLACEMENT WITH THE PRINTER
POWER ON !!!
******************************************************************