Circuit Board Division
800.261.3602
2
Revised 02/21
Table of Contents
Modes of Relay Operations
.........................................
3
LED Indication Description
..........................................
3
Operational Thresholds
...............................................
3
Typical Wiring Diagram
…….. .......................................
4
Option 1 Diagram
.........................................................
5
Option 2 Diagram
.........................................................
5
Option 3 Diagram
.........................................................
5
Option 1 Starting Sequence
........................................
6
Option 2 Starting Sequence
........................................
7
Option 3 Starting Sequence
........................................
8
Manual Off Auto Switch Options
...............................
9
Fault Shutdown Conditions
.........................................
9
Automatic Starting for Battery Charging
.................
10
Generator Emergency Shutdown
.............................
10
LED Description and Meanings
.................................
11
Specifications
..............................................................
11
Remote RV Generator Start Drawing
................
12
Outback Inverter/Inverter Style Drawing
.........
13
Outback Inverter/Honda EUxx00is Drawing
....
14
Samlex America EVO Inverter Drawing
.............
15
Limited Warranty
.....................................................
16
Solving your generators two to
three wire start-stop problem.
Not Included But…….
Outback 48 Volt inverter
systems require isolation relay
A0365
Features & Applications
Inexpensive 2 wire to 3 wire start controller for
electric push to start/stop Duel fuel generators
Optimized for use with Outback Invertors
Supports four manufactures generator control:
Champion, Cummins/Onan, Duramax and
Westinghouse
Fixed start/stop pulse times, accounts for
multiple start attempts by generator’s ECU
Maximum auto-start run time limit (6 hours)
Remote run and fault indication included
ABS epoxy sealed for harsh environment
operation
Description
The GSCM-mini-P (Pulse) is a micro-processor based
generator start-stop module, designed to auto start-
stop generators that need a 3 to 4 wire connection
from a 2 wire 12 volt manual start command. The
GSCM-mini-P automatically goes into run mode
when it either receives a remote start indication
lamp signal (connected to terminal 8) or an AC Hz
signal from the generator (AC connected to terminals
9 & 10). Various LEDs are blinked or turned on to
indicated the run or fault status of the GSCM-mini-P.
Manually resetting the GSCM-mini-P by removing
the power and removes any lockout that allows the
generator to restart if called to do so.
The GSCM-mini-P is powered by 12VDC from the
generator battery and can monitor the battery
voltage and start the generator to charge its own
battery. The GSCM-mini-P is a limited function
controller that is part of the GSCM family.
All auto start battery voltage thresholds are
fixed, if adjustability is required use the GSCM
full function Generator Start Control Module.