ENG - Manual of installation, use and maintenance.
210-0352_libretto_WHC_ATI_eng.docx
15
Jan-19
The hole for passing the exhaust and the air intake pipe through the wall should not be blocked and the flue pipe must be free to
slide through the hole in such a way that it can subsequently be detached. You can use the wall covers supplied with the flue kits
to cover the empty space of the hole.
IMPORTANT: LEAVE A CLEARANCE OF NO LESS THAN 60 CM ABOVE THE APPLIANCE TO ALLOW ANY MAINTENANCE TO THE TOP
OF THE UNIT.
CONNECTION TO THE BOILER
The unit is factory supplied with a Ø60 / 100 polypropylene flue connection, provided with air and flue sampling.
The flue connection is not installed: it is packed together with the unit and positioned at the bottom of it, ready for installation.
IMPORTANT: MAKE SURE YOU HAVE THE SAMPLING PLUGS FACING THE LEFT SIDE OF THE UNIT, TO ENSURE A PRACTICAL USE
OF THEM. A WRONG POSITIONING CAN MAKE THE FLUE ANALYSYS DIFFICULT.