| Micro M5 Manual | v2.0
Innovation In and Out of Parlour
The Feeding Settings Menu Structure for Rotary Parlours
The Feeding Settings menu is structured as shown below;
Entry point into Feeding Settings menu.
Menu loops back around to the Enable feeding setting.
ENABLE FEED OFF
ê
FEEDER OFFSET 4
ê
ê
Feeder Offset: This setting is the number of stalls behind
the identification stall where the feeder will feed.
Enable Feed: The enable / disable feeding global setting,
if set to off, other menu items are blocked from access.
Individual Feeder Calibration: This setting allows the
user to individually calibrate each feeder.
FEEDER CALI
ê
BIN LEVEL
BW LEVEL 25
ê
ê
Feed Bin Level: Level in kilograms for the feed bin,
allows for a warning when the feed bin is getting low.