A
TL
A
g
ricu
ltu
ra
l
Te
ch
n
olog
y
L
imite
d:
S
e
pte
mbe
r
2
0
2
1
54
| Micro M5 Manual | v2.0
Innovation In and Out of Parlour
The Rotary Settings Menu Structure
The Rotary Settings menu is structured as shown below;
Entry point into Rotary Settings menu.
Menu loops around to the Bonker setting, press the Cancel Key to exit.
BONKER ON
BONKER OFFSET 3
ê
BONKER TIME 10
ê
GAP 1 000 TO 000
ê
GAP 2 000 TO 000
ê
GAP 3 000 TO 000
ê
GAP 4 000 TO 000
ê
ê
ê
Bonker Offset: The Bonker Offset setting is the number
of stalls from the entry stall back around the parlour to
where the bonker is located.
Bonker Time: The time the Bonker will be switched on
for.
Gap 1: Stall Gap 1 settings, this is the stall number from
to which are not enabled for identification or milk
meters, allowing for gaps in the rotary parlour.
Gap 2: Stall Gap 2 settings, this is the stall number from
to which are not enabled for identification or milk
meters, allowing for gaps in the rotary parlour.
Gap 3: Stall Gap 3 settings, this is the stall number from
to which are not enabled for identification or milk
meters, allowing for gaps in the rotary parlour.
Gap 4: Stall Gap 4 settings, this is the stall number from
to which are not enabled for identification or milk
meters, allowing for gaps in the rotary parlour.
Enable Exit Bonker: The enable / disable the bonker
system global setting, if set to off, other menu items are
blocked from access.
Gap 5: Stall Gap 5 settings, this is the stall number from
to which are not enabled for identification or milk
meters, allowing for gaps in the rotary parlour.
Identification Offset: This setting allows the
identification to be offset, if during setup it needs to be
moved in reference to the stalls.
GAP 5 000 TO 000
ID OFFSET 0
ê
ê