Section 1 - Overview
O & M Manual
A14-RK, 8/06
1 - 3
INTRODUCTION
GasSens
is an on-line monitoring system for the detection of hazardous gases in ambient
air. It is designed to detect and alarm gas leaks from storage cylinders, process piping, or gas
feed equipment in virtually any type of industrial plant environment. Systems are available for
monitoring a variety of gases as shown in Table 1-1.
TABLE 1-1
GAS
CODE NO.
STD. RANGE
MIN. RANGE
MAX. RANGE
GENERAL GASES
Ammonia
15*
0-100 PPM
0-50 PPM
0-500 PPM
Carbon Monoxide
16*
0-100 PPM
0-50 PPM
0-500 PPM
Hydrogen
18
0-4%
0-2000 PPM
0-10%
Nitric Oxide
25
0-100 PPM
0-25 PPM
0-500 PPM
Oxygen
19
0-25%
0-10%
0-100%
Phosgene
20
0-2 PPM
0-1 PPM
0-100 PPM
OXIDANT GASES
Bromine
10*
0-2 PPM
0-1 PPM
0-100 PPM
Chlorine
11*
0-10 PPM
0-1 PPM
0-100 PPM
Chlorine Dioxide
12*
0-2 PPM
0-1 PPM
0-100 PPM
Fluorine
13*
0-2 PPM
0-1 PPM
0-100 PPM
Hydrogen Peroxide
34
0-10 PPM
0-10 PPM
0-100 PPM
Ozone
14*
0-2 PPM
0-1 PPM
0-100 PPM
Iodine
35*
0-2 PPM
0-1 PPM
0-100 PPM
ACID GASES
Hydrogen Chloride
21*
0-20 PPM
0-10 PPM
0-200 PPM
Hydrogen Cyanide
22*
0-20 PPM
0-10 PPM
0-200 PPM
Hydrogen Fluoride
23*
0-20 PPM
0-10 PPM
0-200 PPM
Hydrogen Sulfide
24*
0-50 PPM
0-10 PPM
0-500 PPM
Nitrogen Dioxide
26*
0-20 PPM
0-5 PPM
0-200 PPM
Sulfur Dioxide
27*
0-20 PPM
0-10 PPM
0-200 PPM
HYDRIDE GASES
Arsine
28
0-1000 PPB
0-1000 PPB
0-100 PPM
Diborane
29
0-1000 PPB
0-1000 PPB
0-100 PPM
Germane
30
0-1000 PPB
0-1000 PPB
0-100 PPM
Hydrogen Selenide
31
0-1000 PPB
0-1000 PPB
0-100 PPM
Phosphine
32
0-1000 PPB
0-1000 PPB
0-100 PPM
Silane
33
0-10 PPM
0-1000 PPB
0-100 PPM
* Auto-Test is available in these gases.
The
GasSens
system consists of modular components that can be used in a variety of
configurations to fit specific application requirements. A description of the major system
components follows: