D12
EX-IR
Gas Transmitter with IR Smart Sensor
Dec 2019 ( 85-0004 Rev A)
76
Security Menu
The transmitter can guard against unauthorized changes to its configuration through the front panel.
When security is active, settings may be read, but not modified, and methods will not execute, including
verifications during Sensor Review (see page 31). To make changes, security must be disabled, either
permanently or temporarily, by entering the correct 4-digit code. Panel security status is indicated on the
Main Display as shown on page 32.
Figure 86. Security Menu
Activating Security
The following display sequence appears when attempting to activate panel security.
Figure 87. Activating Security
Item
Select to …
Active
Activate or deactivate panel security. You must enter the
panel code in either case. See Figure 87. Activating Security
and Figure 88. Deactivating Security, below.
Change Code
Change the panel code.
Change Code
Security
Code= Fail
Enter code to . .
…Security>Code Entry
Security
Code= 0
Enter code to . .
…Security>Code Entry
Security
Code= Pass
Enter code to . .
…Security>Code Entry
Security
►Ac
tive= No
Change Code
…Panel>Security
Security
►Ac
tive= Yes
Change Code
…Panel>Security