Manual, Compliant Reciprocating Tool, CRT Series
Document #9610-50-1028-04
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 USA • Tel: +1.919.772.0115 • Fax: +1.919.772.8259 • www.ati‑ia.com
20
6.2 Service Procedures
Component replacement and adjustment procedures are provided in the following section:
CAUTION:
During operation of the reciprocating tool, the file reaches high
temperatures. Failure to wear proper personal protection equipment or not allowing
the file to cool could result in serious injury to the user. Be aware that during operation,
the file becomes very hot, and removing the bur, take necessary safety precautions
to avoid injury.
6.2.1 File Replacement
The file becomes worn during normal operation. If improper feeds and speeds are used, the file
may become “loaded” with material. In both instances, replace the file. During initial production,
the file and the workpiece should be examined often in order to determine when the file
should be replaced.
Refer to the following steps for replacing the file (
Tools required: 2.5 mm hex key
1. Lock‑out and remove the reciprocating drive air supply for safety. De‑energize all energized
circuits such as: air and power.
2. Use a 2.5 mm hex key to loosen the (2) M5 set screws in the body of the file holder.
3. To remove a worn file, pull the file out of the holder by hand.
4.
Replace the file.
5. Use a 2.5 mm hex key to tighten the (2) M5 set screws in the body of the file holder securing
the file in place.