![Athena A060-Mini Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/athena/a060-mini/a060-mini_installation-and-user-manual_2998347017.webp)
Page 13
Wireless Communications
5.4 SNMP interface
Object
OID
OID type
Description
MIB-2
(iso.org.dod.internet.mgmt.mib-2.sysem.x / .1.3.6.1.2.1.1.x)
sysDescr
.1.
DisplayString
Includes serial no.
sysUpTime
.3.
TimeTicks
Uptime of the network management
sysName
.5.
DisplayString
set in the web GUI
sysLocation
.6.
DisplayString
set in the web GUI
ATHENA-MIB A060-Mini
(iso.org.dod.internet.private.enterprises.athenaminiOID.mini.x / .1.3.6.1.4.1.36043.1.x)
A060-MiniLinkQuality
.1.
Integer
1: Green
2: Yellow
3: Red
A060-MiniReceivePower
.10.
Integer
Receive signal level [dBm]
A060-MiniTemperature
.11.
Integer
Temperature [˚C]
A060-MiniLocDetector
.12.
Integer
Lock detection signal level
A060-MiniifEthernetIn
.15.
Integer
Total frames received on the Ethernet interface over a
period of 10 seconds.
A060-MiniifEthernetOut
.16.
Integer
Total frames sent on the Ethernet interface over a
period of 10 seconds.
A060-MiniifEthernetError
.17.
Integer
Total frames dropped due to errors received on the
Ethernet interface over a period of 10 seconds
A060-MiniifAirIn
.18.
Integer
Total frames received on the Air interface over a period
of 10 seconds.
A060-MiniifAirOut
.19.
Integer
Total frames sent on the Air interface over a period of
10 seconds.
A060-MiniifAirInError
.20.
Integer
Total frames dropped due to errors received on the Air
interface over a period of 10 seconds.
A060-MiniFirmwareversion
.21.
String
Installed firmware version
ATHENA-MIB A060-Minitraps
(iso.org.dod.internet.private.enterprises.athenaminiOID.mini.miniTraps.x / .1.3.6.1.4.1.36043.1.22.x)
A060-MiniLinkQualityImprovedTrap
.1.
Integer
1: from red to green
2: from red to orange
3: from orange to green
A060-MinilinkQualityReducedTrap
.2.
Integer
1: from red to green
2: from red to orange
3: from orange to green
A060-MiniTemperatureHighTrap
.3.
Integer
A trap indicating that the temperature within the unit is
at or
above
70 degree Celcius
A060-MiniTemperatureLowTrap
.4.
Integer
A trap indicating that the temperature within the unit is
at or below -40 degree Celcius
Содержание A060-Mini
Страница 1: ...Wireless Communications Installation and User Manual A060 Mini Revision B ...
Страница 2: ......
Страница 4: ...Wireless Communications ...
Страница 22: ...Page 18 Wireless Communications A Map Of America ...
Страница 23: ...Page 19 Wireless Communications B Map of Asia and Middle East ...
Страница 24: ...Page 20 Wireless Communications C Map of Europe ...