Athena A060-Mini Скачать руководство пользователя страница 1

                                                                                                                                          

Wireless Communications

 

Installation and User Manual     

A060-Mini

®

 

Revision B 

 
 

                    

 

Содержание A060-Mini

Страница 1: ...Wireless Communications Installation and User Manual A060 Mini Revision B ...

Страница 2: ......

Страница 3: ...htning protection 1 3 7 Co located applications 1 4 INSTALLATION 1 4 1 Mount installation 1 4 1 1 Wall mount 1 4 1 2 Mast mount 1 4 2 Terminal installation 1 4 3 Cable installation 1 4 4 Antenna alignment 1 4 4 1 Alignment Procedure 4 4 1 1 Optical alignment 4 4 1 2 Power level alignment 4 5 Grounding 4 6 Lightning Surge protector 4 7 Power injector 5 TERMINAL MANAGEMENT AND MONITORING FUNCTIONS 5...

Страница 4: ...Wireless Communications ...

Страница 5: ...er extent it shall deem necessary to restore the product or components to full operating condition Any replacement will consist of a new or remanufactured functionally equivalent product of equal value and will be offered solely at the discretion of Athena Wireless This warranty shall not apply if the product is modified e g warranty seal is broken misused tampered with damaged by an act of God or...

Страница 6: ...an alignment bracket allow the user to easily install the link Immediate operation without the need for additional configuration is granted Network performance Guaranteed full duplex at 1000 Mbps along the complete range Unlike typical WLAN equipment the user can transmit a full 1000 Mbps over the link License free operation The system has been approved and can be operated in many countries System...

Страница 7: ...A Terminal A Bracket Mounting set Carton B Terminal B Bracket Mounting set Carton C Manual Reset CD Ice bridges Accessories Required tools 5mm adjustable end wrench 2 3 System components The A060 Mini system is composed of the following components Terminal A and Terminal B Alignment bracket Alignment tool Ice bridge Sealed Ethernet connection Main accessories PoE injector Mast bracket Ethernet cab...

Страница 8: ...er compatible network equipment or a PoE injector 2 3 2 Alignment bracket The alignment bracket facilitates easy radio alignment owing to its independent axises It has coarse and fine alignment capabilities 2 3 3 Alignment tool The optical alignment tool provided is easily mounted on the terminal using the locator pins and large thumb screw It enables both ends of the link to be aligned quickly si...

Страница 9: ...to the IEEE 802 3at PoE standard Should the network equipment connected to the A060 Mini link not offer PoE a power injector can be inserted in line with the Ethernet cable 2 3 5 2 Mast bracket accessory The mast bracket is used to mount the bracket onto a mast The bracket is suitable for any pole diameter from 50 mm to 115 mm 2 to 4 5 ...

Страница 10: ...blished visually using the following table 1 3 3 Link distance Link availability The link distance is directly related to the weather conditions The affordable link availability is influenced by the following environmental conditions Rain the less the better Temperature the higher the better Air pressure the lower the better Knowledge of the link distance line of sight is important in estimating l...

Страница 11: ... voltage surges In the event of a short circuit or lightning strike effective grounding can prevent damage to building equipment infrastructure and personnel For installations in the USA refer to Article 830 of the National Electrical Code Network powered broadband communications systems For all other countries implement protection in accordance with the safety standards and regulatory requirement...

Страница 12: ...eter of between 50 mm to 115 mm 2 to 4 5 Fasten the mast bracket onto the mast using the enclosed stainless steel screws nuts and washer M6 Fasten the alignment bracket onto front part of the mast bracket using the enclosed stainless steel screws nuts and washer M6 Do not use zinc plated screws as these will corrode and endanger link performance and safety to people and equipment 4 2 Terminal inst...

Страница 13: ...ignment for all operations the enclosed 5 mm allen key can be used 4 4 1 1 Optical alignment 1 Place the alignment tool to the most accessible corner and ensure good visibility to the opposite terminal by rotating the telescope 2 Loosen the horizontal lock screws labeled 3 3 Place the horizontal axis course screw in its middle position needle 4 Carry out a rough alignment on the horizontal axis an...

Страница 14: ... the terminal to the connection points nearest to the building to earth ground point The grounding conductor must be as short as is practical and should not exceed 6 m 20 ft For installations in the USA refer to Articles 830 of the National Electrical Code Network powered broadband communications systems For installations in all other countries refer to the safety standards and regulatory requirem...

Страница 15: ...divided into five sections Overview Wireless Network System and Status 5 1 1 Overview This screen shows an overview of key link information including but not limited to its serial number version mac address temperature and current status 5 1 2 Wireless The wireless screen is divided into setup and status Setup gives the Terminal type A or B transmit and receive frequencies and the transmit power T...

Страница 16: ...unity settings and the IP address to send system alerts The third section of this screen is where you enable or disable alerts and temperature alert and set the temperature high and low limits for triggering an alert 5 1 5 Status The status screen like the overview screen is an information only screen It too is divided into three sections The first gives information on the life uptime current upti...

Страница 17: ...netError 17 Integer Total frames dropped due to errors received on the Ethernet interface over a period of 10 seconds A060 MiniifAirIn 18 Integer Total frames received on the Air interface over a period of 10 seconds A060 MiniifAirOut 19 Integer Total frames sent on the Air interface over a period of 10 seconds A060 MiniifAirInError 20 Integer Total frames dropped due to errors received on the Air...

Страница 18: ... and B respectively All terminals on the network must have a unique IP address in the same range e g 192 168 1 X Any terminal with identical IP addresses will not be visible on the network They must all also have the same subnet mask e g 255 255 255 0 Do a Ping test to make sure that the A060 Mini is responding Go to Start Run Type Command Type ping 192 168 1 21 22 A successful Ping test will gene...

Страница 19: ...duplex Interfaces 1000 Base T Latency 50 µs distance 1 µs 300 m Range up to 1000 m 3280 ft Availability up to 99 999 Warranty 1 year Connection Cable Length max 100 m 300 ft Signal Wires CAT 5e Connector RJ 45 male including outdoor Ethernet seal kit Mechanical data Dimension 182 mm x 182 mm x 89 mm 7 1 x 7 1 x 3 5 ...

Страница 20: ...49 F 131 F Storage Temperature 30 C 55 C 22 F 131 F Wind Load operating 160 km h 100 mph survival 200 km h 125 mph Regulatory Regulatory Compliance FCC Part 15 Industry Canada RSS210 R TTE Directive 1999 5 EC Ordering information A060 Mini Item A060 Mini Item each composed of 2 Terminals 2 Alignment brackets 1 Manual 2 Mounting sets The range depends on the climate zone and the requested availabil...

Страница 21: ... G H J K L M N P Q 99 797 789 785 764 787 770 752 765 701 772 765 741 730 669 597 99 9 765 752 730 701 719 701 669 684 618 669 648 607 549 461 446 99 99 701 669 648 624 607 578 569 561 549 524 473 466 405 343 376 99 999 607 561 524 524 450 434 461 425 486 397 338 370 312 268 320 Rain zone according to ITU R Recommendation PN 837 1 99 9 availability equates to 526 minutes per year of outage due to ...

Страница 22: ...Page 18 Wireless Communications A Map Of America ...

Страница 23: ...Page 19 Wireless Communications B Map of Asia and Middle East ...

Страница 24: ...Page 20 Wireless Communications C Map of Europe ...

Страница 25: ...o guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equip...

Страница 26: ...emonstrate the compliance of low power electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields 10 MHz 300 GHz EN 55022 2006 Information technology equipment Radio disturbance characteristics Limits and methods of measurement EN 55024 1998 Information technology equipment Immunity characteristics Limits and methods of measurement EN 60950 ...

Страница 27: ...Page 23 Wireless Communications C CONTACTS C 1 Technical assistance Please visit http www athenawave com C 1 2 Service center RMA ...

Отзывы: