![ATH-Heinl M72Z Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/ath-heinl/m72z/m72z_user-manual_2998296033.webp)
® Copyright by ATH-Heinl GmbH & Co. KG, 2019, All rights reserved / Misprint and technical changes reserved / Issue: 2019/02
- 33 -
Maintenance and service instructions
All maintenance and service works should be done at least once a month
COMPRESSED AIR MAINTENANCE UNIT
ADJUSTMENT OF WORKING PRESSURE:
•
Check the working pressure which is indicated in
the manometer (1). The pressure must fulfil the
technical data.
•
The working pressure can be adjusted by means
of the pressure controller (A).
•
Pull the pressure controller upwards to adjust.
•
For increasing the pressure in the machine, you
must turn the pressure controller clockwise, for
decreasing the pressure you must turn it
counter-clockwise.
OILER
•
Check the oil level in the oil tank (3)
•
Remove the oil tank
•
Refill now the tank accordingly with a pneumatic
oil, viscosity SAE20.
•
Check the rate of injection of the oil in the
viewing glass (4). The oiler is working correctly
if one drop of oil injects automatically into the
compressed air system while pressing the bead
breaker twice.
•
If this is not the case, the oil quantity to be
injected must be adjusted with the regulating
screw (C).
o
Normally the screw must be tightened
completely clockwise and then opened
approx. ¼ to ½ rotation counter-
clockwise.
WATER SEPARATOR
•
Check the water level in the separator (2).
•
By opening the valve (B) the water will be
drained.
B
C
A
1
4
2
3
Содержание M72Z