® Copyright ATH-Heinl GmbH & Co. KG, 2019, All rights reserved / Misprints and technical changes reserved / As of: 2019-01
Manufacturer ATH-Heinl GmbH & CO.KG
- 26 -
4.4
Maintenance or Service Plan
Interval
Im
m
ed
ia
te
ly
W
ee
kl
y
M
on
th
ly
Ev
er
y
3
m
on
th
s
Ev
er
y
6
m
on
th
s
Check of ALL safety-relevant parts
X
Cleaning
X
Check or restore surface protection
X
Check for leaks in the hydraulic system
X
Check or restore surface protection or corrosion protection
X
Check or restore damage to the paint and components
X
Check or restore rust damage
X
Check or treat cavities and non-painted areas
X
Check for leaks in the pneumatic system
X
Control the tightness of screws
X
Check, lubricate & adjust bearing slack
X
Check wear parts
X
Check fluids (level, wear, contamination, quality)
X
Check and lubricate sliding surfaces
X
Remove any dirt inside
X
Clean and check electrical components
X
Check motor and transmission for function and wear
X
Check welds and construction
X
Visual inspection (according to inspection plan)
X