ATESS EVD-60D Скачать руководство пользователя страница 8

10

9

No.

Parameters

Function description

1

2

3

Charger IP

Server URL2

Server URL1

Server address setting, used to set domain or IP 
address of back-office server.

IP setting of the charging equipment

Address of backup server. This parameter is not 
available now, reserved for future use.

4

Subnet mask

Subnet mask setting

5

Gateway

Gateway setting

6

DNS

DNS server address

7

MAC Addr

MAC address

8

Server IP

Server IP address

9

Server port

Server port number

10

WIFI SSID

WIFI SSID setting, to set the name of the wireless 
network to which the charging equipment is to 
be connected. A reserved function for future use

11

WIFI Key

WiFi password setting. A reserved function for 
future use

12

Authentication Key OCPP login authentication setting

No.

Parameters

Function description

1

2

3

4

5

6

7

8

9

DC output overvoltage value

DC output overcurrent value

AC input overvoltage value

AC input undervoltage value

AC input overcurrent value

DC output limit power

Charger over temperature value

Charger derate temperature value

Insulation Resistance

Over voltage limit setting of DC 
output

Over current limit setting of DC 
output

Over voltage limit setting of AC
 input

Under voltage limit setting of AC 
input

Over current limit setting of AC
 input

Power limitation setting of DC
 output

Over temperature limit setting of 
charging connector

Charging connector’s temperature 
at which the charging equipment 
starts decreasing output power

The min value of insulation 
resistance

If  the  charger  is  connected  to  the  server  through  the  network  cable,  the  Charger 
IP, Subnet mask and Gateway need to be set. Through WiFi, you need to set WiFi 
SSID  and  WiFi  Key.  With  4G,  you  can  connect  to  the  server  by  installing  a  SIM 
card.

4.3 Protection parameters

The protection-related parameters, such as voltage, current, temperature, power, 
etc.

Содержание EVD-60D

Страница 1: ...t user manual 86 755 2998 8492 T Shenzhen Atess Power Technology Co Ltd 3rd floor building 9 Henglong industrial park the fourth industrial zone of Shuitian community Baoan district Shenzhen China E i...

Страница 2: ...ly for electric vehicles which has a friendly man machine interface and integrates corresponding functions of control billing communication and security protection The charging equipment uses OCPP 1 6...

Страница 3: ...stem Parameters 4 2 Network parameters 4 3 Protection parameters V Operation instruction and LCD introduction 5 1 Charging mode and operation 5 2 LCD interface introduction 5 3 Appendix Fault code VI...

Страница 4: ...erson can operate the breaker in the surge protection circuit and replace the lightning protection module The red circle in the figure is the lightning protection status indicator When the indication...

Страница 5: ...area to avoid flooding water 2 The foundation pile is to be made of reinforced concrete which requires for a minimum allowable bearing pressure of 1000kg squire meters for the base 3 Construct main gr...

Страница 6: ...and phase sequence The earth cable shall be connected to the grounding bar of the charger Wiring illustration is shown in elow Please notice For safety the charger must be grounded securely Connect th...

Страница 7: ...charge mode payment is not needed 2 is APP or RFID mode No Parameters Function description 8 9 10 Time set Language set Meter address DC meter s modbus address already preset in factory it is not allo...

Страница 8: ...rvoltage value DC output overcurrent value AC input overvoltage value AC input undervoltage value AC input overcurrent value DC output limit power Charger over temperature value Charger derate tempera...

Страница 9: ...and payment provided that the back office server supports such function 4 5 2 3 1 APP RFID mode operation process flow Plug Charge Charging will start automatically after EV plugged in If you want to...

Страница 10: ...when entering each parameter setting page Password window Before entering numeric please first press the text display field to move the cursor there then you can type in the 4 digit password A wrong p...

Страница 11: ...e disconnection fault AC Contactor sticking fault AC Input Overvoltage AC Input Undervoltage BMS communication fault VI Specification Model EVD 60D Dimension mm 1883 600 743 W H D Weight kg 240KG Disp...

Страница 12: ...C output Over temperature protection Short circuit protection Emergency stop protection Lightning protection Leakage protection 20 50 Ip54 95 2000m derate for higher than 2000m Forced air cooling Ethe...

Страница 13: ...etc 4 Failure or damage caused by the installation repair modification or disassembly byunauthorized service personnel 5 Failure or damage caused by using ATESS Power Technology s genuine spare parts...