 I. Product description

Crimp  the  below  shown  ring  terminals  on  the  end  of  the  AC  input  wires  and  PE 
wires. 
Connect the wires into the terminal block of the chargepoint as below. 
Check the wiring  then close the switch and the door.

Fig: AC Surge protection device

Note:  The  charging  equipment  will  detect  the  current  status  of  the  lightning 
arrester  module  in  real  time.  When  the  lightning  protection  module  is  damaged, 
the  display  will  have  an  alarm  indicating  that  the  lightning  protection  device  is 
faulty.  When  repairing  and  replacing  the  lightning  protection  module.  Then  the 
maintenance  person  can  operate  the  breaker  in  the  surge  protection  circuit  and 
replace the lightning protection module.(The red circle in the figure is the lightning 
protection  status  indicator.  When  the  indication  window  indicates  green,  the 
lightning  protection  module  is  normal;  when  the  indication  window  indicates  red, 
the lightning protection module has been broken and damaged, and the lightning 
protection module needs to be replaced.)

Internal view and terminal definition

1.Breaker in surge protection circuit;
2.SPD
3.AC input terminal block. Terminal definition is 

(

L1

;

L2

;

L3

;

N

) from left to 

right;

4.PE terminal;

1. CHAdeMO connector indicator(charging yellow/fault red)
2. Power indicator
3. CCS connector indicator(charging yellow/fault red)
4. HMI
5. Emergency stop button
6. RFID reader
7. CHAdeMO
8. CCS

Содержание EVD-60D

Страница 1: ...t user manual 86 755 2998 8492 T Shenzhen Atess Power Technology Co Ltd 3rd floor building 9 Henglong industrial park the fourth industrial zone of Shuitian community Baoan district Shenzhen China E i...

Страница 2: ...ly for electric vehicles which has a friendly man machine interface and integrates corresponding functions of control billing communication and security protection The charging equipment uses OCPP 1 6...

Страница 3: ...stem Parameters 4 2 Network parameters 4 3 Protection parameters V Operation instruction and LCD introduction 5 1 Charging mode and operation 5 2 LCD interface introduction 5 3 Appendix Fault code VI...

Страница 4: ...erson can operate the breaker in the surge protection circuit and replace the lightning protection module The red circle in the figure is the lightning protection status indicator When the indication...

Страница 5: ...area to avoid flooding water 2 The foundation pile is to be made of reinforced concrete which requires for a minimum allowable bearing pressure of 1000kg squire meters for the base 3 Construct main gr...

Страница 6: ...and phase sequence The earth cable shall be connected to the grounding bar of the charger Wiring illustration is shown in elow Please notice For safety the charger must be grounded securely Connect th...

Страница 7: ...charge mode payment is not needed 2 is APP or RFID mode No Parameters Function description 8 9 10 Time set Language set Meter address DC meter s modbus address already preset in factory it is not allo...

Страница 8: ...rvoltage value DC output overcurrent value AC input overvoltage value AC input undervoltage value AC input overcurrent value DC output limit power Charger over temperature value Charger derate tempera...

Страница 9: ...and payment provided that the back office server supports such function 4 5 2 3 1 APP RFID mode operation process flow Plug Charge Charging will start automatically after EV plugged in If you want to...

Страница 10: ...when entering each parameter setting page Password window Before entering numeric please first press the text display field to move the cursor there then you can type in the 4 digit password A wrong p...

Страница 11: ...e disconnection fault AC Contactor sticking fault AC Input Overvoltage AC Input Undervoltage BMS communication fault VI Specification Model EVD 60D Dimension mm 1883 600 743 W H D Weight kg 240KG Disp...

Страница 12: ...C output Over temperature protection Short circuit protection Emergency stop protection Lightning protection Leakage protection 20 50 Ip54 95 2000m derate for higher than 2000m Forced air cooling Ethe...

Страница 13: ...etc 4 Failure or damage caused by the installation repair modification or disassembly byunauthorized service personnel 5 Failure or damage caused by using ATESS Power Technology s genuine spare parts...

Отзывы: