I. Product description
1. HMI; 5. LED indicators;
2. RFID reader; 6. Air outlet;
3. Air inlet; 7. Mounting bracket;
4. Charging connector holder; 8. Emergency Stop button;
Explanation of LED indicators behaviors:
Blue - Standby(The charging equipment can only be used when the blue light lit);
Red Steady on/Flashing - Fault;
Green Steady on - Charging in process;
Green Flashing - Establishing communication;
Yellow Flashing - System initializing.
Internal view and terminal definition
1. PE terminal;
2. AC input terminal block. Terminal definition is (
①
L1;
②
L2;
③
L3;
③
N) from left to
right;
3. AC input RCBO;
4. Breaker in surge protection circuit;
5. SPD
Fig: AC Surge protection device
Note: The charging equipment will detect the current status of the lightning arrester
module in real time. When the lightning protection module is damaged, the display
will have an alarm indicating that the lightning protection device is faulty. When
repairing and replacing the lightning protection module, the left side cover must be
removed first. Then the maintenance person can operate the breaker in the surge
protection circuit and replace the lightning protection module! (The red circle in the
figure is the lightning protection status indicator. When the indication window
indicates green, the lightning protection module is normal; when the indication
window indicates red, the lightning protection module has been broken and
damaged, and the lightning protection module needs to be replaced.)
1
2
3
4
5