5.3 Appendix: Fault code
No.
Fault description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Emergency stop is pressed!
RFID communication fault!
Lightning protection fault!
Power module communication fault!
Over temperature fault!
DC output overvoltage fault!
Meter communication fault!
DC output overcurrent fault!
Waiting for BMS communication timeout!
Insulation detection timeout!
Insulation detection fault!
DC+ Contactor sticking fault!
DC- Contactor sticking fault!
Battery voltage reverse fault!
Plug head connection over temperature fault!
Plug line disconnection fault!
AC Contactor sticking fault!
AC Input Overvoltage!
AC Input Undervoltage!
BMS communication fault!
VI. Specification
Model
EVD-40S
Dimension(mm)
548*775*294(W*H*D)
Weight(kg)
55KG
Display
LCD
Casing material
AC input
Grid connection
Current
Voltage
DC output
Stainless steel&acrylic sheet
Voltage
400V, 3 phase 5 wires
AC 260~530V
64A
45~
65HZ
DC150~
750V
Frequency
Current
Voltage-stabilizing accuracy
Current-stabilizing accuracy
Power factor
Efficiency
0~67A HV mode(400V-750V) continuously
adjustable/ 0~80A LV mode(150V-400V)
continuously adjustable
0.5%
0.95 @20
%~
50
%
of full load output power
1
%(
at 20
%~
100
%
of rated power)
0.98 @50
%~
100
%
of full load output power
0.99 @100
%
full load output power, rated
input voltage and frequency
95.2
%
,
@
750V, 50
%~
100
%
of rated current
and rated input voltage