ATESS EVD-40S Скачать руководство пользователя страница 1

EVD-40S 40KW 

DC charging equipment user manual 

 + 

86 755 2998 8492

T

Shenzhen Atess Power Technology Co.,Ltd

3rd floor, building 9, Henglong industrial park, the fourth industrial zone of Shuitian community, 

Baoan district, Shenzhen, China

E

 

[email protected]

W

www.atesspower.com

Содержание EVD-40S

Страница 1: ...ser manual 86 755 2998 8492 T Shenzhen Atess Power Technology Co Ltd 3rd floor building 9 Henglong industrial park the fourth industrial zone of Shuitian community Baoan district Shenzhen China E info...

Страница 2: ...charging equipment is a device that provides high efficiency safe and stable DC power supply for electric vehicles which has a friendly man machine interface and integrates corresponding functions of...

Страница 3: ...stem Parameters 4 2 Network parameters 4 3 Protection parameters V Operation instruction and LCD introduction 5 1 Charging mode and operation 5 2 LCD interface introduction 5 3 Appendix Fault code VI...

Страница 4: ...protection device Note The charging equipment will detect the current status of the lightning arrester module in real time When the lightning protection module is damaged the display will have an ala...

Страница 5: ...nd 3 holes for cable hooker mounting on the wall Take out the expansion bolts in thepacking accessory bag hammer the expansion bolts into the holes Remove the nuts and washers for later use 2 Loosen t...

Страница 6: ...the upper cover after checking internal wiring and breaker position The wiring is then finished Notice 1 Only professional personnel can do the wiring connect the AC input wires in correct phase order...

Страница 7: ...payment is not needed 2 is APP or RFID mode No Parameters Function description 8 9 10 Time set Language set Meter address DC meter s modbus address already preset in factory it is not allowed to modi...

Страница 8: ...Authentication Key OCPP login authentication setting 4 3 Protection parameters The protection related parameters such as voltage current temperature power etc No Parameters Function description 1 2 3...

Страница 9: ...e Charging will start automatically after EV plugged in If you want to stop the charging just press the stop icon on the screen Plug Charge mode operation process flow The charging equipment is equipp...

Страница 10: ...ype in the 4 digit password A wrong password will cause no response and action System parameters page Network parameters page used to set network related parameters of back office server and the charg...

Страница 11: ...Contactor sticking fault AC Input Overvoltage AC Input Undervoltage BMS communication fault VI Specification Model EVD 40S Dimension mm 548 775 294 W H D Weight kg 55KG Display LCD Casing material AC...

Страница 12: ...Over temperature protection Short circuit protection Emergency stop protection Lightning protection Leakage protection 20 50 derate since 50 Ip54 5 95 2000m derate for higher than 2000m Forced air co...

Страница 13: ...etc 4 Failure or damage caused by the installation repair modification or disassembly byunauthorized service personnel 5 Failure or damage caused by using ATESS Power Technology s genuine spare parts...

Отзывы: