Chapter 4. Browser Operation
61
Customized Mode
Use the
Customized
mode to automatically retrieve and save the EDID of a
connected monitor/display device to an input source port.
In the left panel, select
Customized
from the EDID Mode section and
click
Apply
.
Port EDID Status
: Select the input source port to which you want to store
the EDID configuration.
Retrieve EDID
: Click this button to retrieve the EDID of a selected port.
Select a port using the pop-up screen.
The right panel displays a summary of the acquired EDID settings that
you can edit. Click
Save
and select the configuration for the
Current
Port
or
All Ports
for the duration of the session.