Chapter 2. Hardware Setup
27
Serial Console Server Installation
SN0108CO / SN0116CO / SN0132CO / SN0148CO Installation
To set up your SN0108CO / SN0116CO / SN0132CO / SN0148CO
installation, refer to the Installation Diagram on page 29. The numbers in the
diagram correspond to the numbers of the instruction steps, below:
1. Use a grounding wire to ground the unit by connecting one end of the wire
to the Serial Console Server’s grounding terminal (located on the back
panel), and the other end of the wire to a suitable grounded object.
Note:
Do not omit this step. Proper grounding helps to prevent damage to
the unit from surges or static electricity.
2. For each server or serial device with a DB-9 connector, connect a Cisco
Console Cable or a Cat 5e cable with RJ-45-to-DB-9(F) adapter between
its serial port and any available RJ-45 port on the Serial Console Server’s
rear panel.
Note:
on page 159 for pin assignments.
3. Connect a Cat 5e cable between a Cisco Network Switch (or any
compatible network switch) and any available RJ-45 port on the Serial
Console Server’s rear panel.
Note:
For a compatible network switch, please make sure the RJ-45 port
pin definition of the target device matches the Serial Console Server.
4. Connect the Serial Console Server to the network by connecting both the
primary and backup LAN ports, located on the unit’s rear panel, to the
network with Cat 5e cables.
5. (Optional) If you choose to install a serial modem for OOB operation,
connect a Cisco Console Cable to a null modem adapter. Plug the DB-9
connector into the Modem and the RJ-45 connector into the Modem Port
on the Serial Console Server’s front panel.
6. (Optional) Connect a Cat 5e cable between an ATEN PDU and the PON
Port on the Serial Console Server’s front panel for power management.
7. (Optional) If you wish to use a console terminal connection, use a Cisco
Console Cable to connect between the Serial Console Server’s Local
Содержание SN01 CO Series
Страница 34: ...Serial Console Server User Manual 20 This Page Intentionally Left Blank...
Страница 45: ...Chapter 2 Hardware Setup 31 SN9108CO SN9116CO Installation Diagram...
Страница 46: ...Serial Console Server User Manual 32 This Page Intentionally Left Blank...
Страница 129: ...Chapter 8 Device Management 115 SN0108CO SN0116CO SN0132CO SN0148CO...
Страница 138: ...Serial Console Server User Manual 124 Association The Association tab is currently reserved...
Страница 152: ...Serial Console Server User Manual 138 This Page Intentionally Left Blank...