- 18 -
Troubleshooting
Specifications
Symptom
Action
Data Transmission
Failure
Check that the IC-485SN units are securely
plugged into the computers' serial ports.
Check that the cables are properly set up and
properly connected.
Check that SW1 and SW2 are set properly.
Data Loss or Error
Check that the Data Rate and Data Format are
the same for all devices.
Power Consumption
6.51 mA
Data Rate
Up to 100 Kbps under 1.2 Km (4000 ft.)
Connectors
•
1 x DB-25 female (for RS-232)
•
1 x 4 Post Terminal Block (for RS-422 / RS-485)
•
1 x RJ-11 Socket (for RS-422 / RS-485)
Function
Switches
SW1
DCE / DTE Select
SW2
•
TxON, RxON
•
TxRTS, RxON
•
TxDTR/RTS, RxDSR/ON
Housing
Plastic
Weight
60 g
Dimensions (L x W x
H)
54 x 74.5 x 18.5 mm
Содержание IC485SN
Страница 1: ......
Страница 17: ... 17 TxDTR RTS RxDSR ON 1 2 DATA DATA RTS CTS DTR TX RX DCE DTE DCE DTE 3 4 BUSY BUST DSR ...