background image

CS1922M / CS1924M RS-232 Commands

3

RS-232 Operation

Overview

The CS1922M / CS1924M’s built-in bi-directional RS-232 serial interface 
allows system control through a high-end controller or PC. RS-232 serial 
operations in a CS1922M / CS1924M installation are managed via 
HyperTerminal sessions on systems that are running Windows. In order to use 
this feature to send commands to the CS1922M / CS1924M, you must first 
download and install a HyperTerminal application. For detailed instructions 
and information about each of the commands provided in this manual, please 
refer to the CS1922M / CS1924M user manual. 

Setup

Install a HyperTerminal application on a computer that is not part of the 
installation, which will be used to control the switch via the RS-232 
connection. HyperTerminal applications can be download from the Internet, 

and many operating systems are embedded with HyperTerminal applications. 

Hardware Connection

Use a RJ-11 to DB-9 serial adapter (LIN5-04A2-J11G) to connect a 

computer’s serial port to the serial

 

port on the CS1922M / CS1924M, as shown 

below:

Содержание CS1922M

Страница 1: ...CS1922M CS1924M 2 4 Port USB 3 0 4K DisplayPort MST KVMP Switch RS 232 Commands V1 0 User Manual www aten com...

Страница 2: ...ause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the f...

Страница 3: ...a HyperTerminal application For detailed instructions and information about each of the commands provided in this manual please refer to the CS1922M CS1924M user manual Setup Install a HyperTerminal...

Страница 4: ...ewer KVM ports RS 232 Pin Assignments Pin assignments for the CS1922M CS1924M s rear RJ 11 Serial Port that is used for connecting to a serial terminal are given in the table below Note This RJ 11 fem...

Страница 5: ...establish a HyperTerminal session using the instructions below 1 Open the HyperTerminal application and configure the port settings for COM1 port then click OK Bits per Second 19200 Data Bits 8 Parity...

Страница 6: ...erial connection is closed For detailed information about the controls listed in this guide please refer to the CS1922M CS1924M user manual Verification After entering a command a verification message...

Страница 7: ...inutes if no command is sent The default value is close Use the Formula to set Parameters to create a Command Formulas Command Enter Parameters Open Close RS 232 Link Command The available formulas fo...

Страница 8: ...itch Port Commands Some available formulas for the Switch Port commands are as follows 1 Command Control Enter For example to switch to port 2 type the following sw i02 Enter Note The Control command...

Страница 9: ...Formula Command Control Enter Parameters Set Baud Rate Commands Some available formulas for the Set Baud Rate commands are as follows 1 Command Control Enter For example to set the baud rate to 19200...

Страница 10: ...ollows 1 Command Control Enter For example to change the keyboard language layout to Japanese type the following layout jp Enter 2 Command Control Enter For example to change the keyboard language lay...

Страница 11: ...ds Some available formulas for Hotkey Setting commands are as follows 1 Command Control Enter For example to change the HSM invoke key to Num Lock type the following hotkey num Enter 2 Command Control...

Страница 12: ...tkey Switching commands are as follows 1 Command Control Enter For example to change the hotkey switching key to Scroll Lock Scroll Lock type the following switch scroll Enter 2 Command Control Enter...

Страница 13: ...te a Command Formulas Command Control Enter Parameters USB Reset Command The available formula for the USB Reset command is as follows 1 Command Control Enter For example to reset the USB connection t...

Страница 14: ...rmulas Command Control Enter Parameters Restore Default Value Command The available formula for the Restore Default Settings command is as follows 1 Command Control Enter For example to restore all CS...

Страница 15: ...ommand Formulas Command Control Enter Parameters Firmware Upgrade Command The available formula for the Firmware Upgrade command is as follows 1 Command Control Enter For example to enable firmware up...

Страница 16: ...e KVM Status command is as follows 1 Command Control Enter For example to display the CS1922M CS1924M s configuration status type the following status on Enter A message similar to the one below will...

Страница 17: ...s for Change Display Mode commands are as follows 1 Command Control Enter For example to set the switch to use SST mode type the following display sst Enter 2 Command Control Enter For example to set...

Отзывы: