SL150 MANUAL
3
118093-001 REV B
INTKL OPEN
: Indicates the EXTERNAL
INTERLOCK connections are in the open position.
This also indicates opening of internal power supply
interlocks.
OVERVOLT:
Indicates the overvoltage protection
circuitry has caused the power supply to turn off.
Overvoltage protection is internally set to 110% of
the rated output voltage.
OVERCURR
: Indicates the output current has
exceeded the programmed current trip level when the
AOL (Adjustable Overload Trip) or the OL
(Overload Trip) options are installed.
OVERPOWER:
Indicates the output power has
exceeded the internally set level or the remote
programmed level if the optional circuitry is
installed.
ARC
: Indicates that an arc has occurred within the
previous one second or that the ARC COUNT/TRIP
has shutdown the power supply.
RGLT ERR:
Indicates a failure in the voltage,
current or power regulation circuitry. This fault
usually occurs when there is a lack of output power
to maintain regulation.
The options available are listed in Table 1.1. See Section
5 for more information on these options along with
operating and set-up instructions. With few exceptions,
these options and modifications can be retrofitted to your
power supply at the factory in a short time. For price and
retrofit arrangements, contact the Spellman Sales
Department.
1.3 Options
AOL
Adjustable Overload Trip (0-103%)
APT
Adjustable Power Trip
AT Arc
Trip
CPC
Constant Power Control
SS(x)
Non-Standard Slow Start
NSS
No Slow Start
LR
Low Ripple (0.05% p-p)
DPM4
4 1/2 Digit
1 Least Significant Digit Panel Mtr
PN Reversible
Polarity
LL (x)
Extra Length Output Cable in Feet
EFR
External Fault Relay
BFP
Blank Front Panel
NAD
No ARC Detect
RFR
Remote Fault Reset
Table 1.1 SL150 Options
Note: APT/CPC cannot be combined with EFR