KK-MLC.010 19.02.21 Rev No:3
5
Pin Number
Cable Color
Signal
1
Yellow
A
2
White
/B
3
Red
POWER SUPPLY
4
Black
0 V
5
Blue
/A
6
Green
B
7
Grey
/Z
8
Pink
Z
9
SHIELD
GROUND
4.
C
ONNECTION
1
2
3
4
5
6
7
8
9
4.1. Pin Connections
In the below table the cable color of the sensor
output signals is given. If the control circuit is
suitable in the Line Driver sensors the output
signal inverts (/A, /B, /Z) must be included in
the system. If the control circuit is not suitable
for this application /A, /B, /Z signal cables must
be immobilized seperately isolated. Don’t
forget that there are also currents on these
cables.
A
/A
B
B
/B
Z
/Z
90
°
Phase
Optional
Every 2 mm, Z Pulse
Standard
One “Z” Reference Signal
(for example at the start point)
2 mm