8.1.
Maintenance Schedule
Inspection, Mandatory Work
Inspection Period
(hours)
10 25 50 100 200
Engine
As per ROTAX Manual attached.
Engine Compartment
Engine Bed
Check integrity of construction with a special focus on welds, fixing
points, silent blocks, bushings. Check surface condition.
x
Bolted Connections
Check surface condition of bolted connections, bearing surfaces. Check
securing and tightening. Tighten and re-secure if necessary. Replace
locking nuts, split pins and securing wires.
x
Silentblocks
Check elasticity of engine bearing, integrity of rubber blocks, degree of
permanent deformation. Replace silent blocks if necessary, tighten,
secure.
x
Oil, Water and Fuel Hoses
Check surface integrity, liquid leak proofness, condition of connections,
protection avoiding touch with oscillating parts and exhaust system.
Replace if necessary.
x
Working Liquids
Check level, refill according to instructions of engine producer.
x
Coolers
Check integrity, sealing, purity.
x
Controls
Check control forces, free play, hinges, end stops adjustment, self-
locking. Adjust, secure.
x
Exhaust piping
Check integrity, sealing, surface condition, corrosion degree, springs
condition and springs prestress. Grease ball connections with a special
lubricant.
x
Carburettors
Check surface condition, controls adjustment, condition of elastic
connection flange – integrity, sealing. Replace flange if material
degradations or surface cracks appear.
x
Electric Installations
Check condition, integrity and purity of cables, insulation, contacts,
welds, bunched cables attachments to airframe and bushings. Check
gauges and senders connections.
x
Propeller Attachment
Check condition of bolts, tightening moments, securing.
x