TH-VW Series Page 3 of 6
X
Y
Contact edge
with the hook
Z
X
Y
=
+
2.3
8 x 17
MAX 225 (7”)
MAX 600 (24”)
8 x 17
8 x 17
STEP A
Combine both heights
to find the height of the contact
edge of the Wall Plate & mark
this on the wall.
STEP B
Position your Wall Plate,
aligning the contact edge to your
mark.
STEP C
Consider lateral location
based on display positions, length
and quantity of Wall Plates.
NOTE
Wall Plate mounting fasteners into load bearing structure to be a MAXIMUM of 600mm (24”) apart
Wall Plate mounting fasteners into load bearing structure to be a MAXIMUM of 225mm (7”) from
end of Wall Plate
Wall Plate to be fixed to wall with a minimum of 3x appropriate load bearing fasteners per Wall Plate
and minimum of 2x appropriate load bearing fasteners per Display
Attach Wall Plate mounting fasteners evenly and regularly along length/s of Wall Plate/s.
2.4
Use the Wall Plate as a template
to mark mounting fastener locations.
IMPORTANT INFORMATION
! Drilling into electrical wires can cause death - use appropriate equipment and caution when drilling holes in walls to avoid electrical
cables, water pipes and gas pipes. Do not drill into structures unless you have established it’s safe to do so.
! Choice and supply of appropriate Wall Plate mounting fasteners is the responsibility of the installer. Consult a structural engineer
where required.
! Wall Plate mounting fasteners are to be used as per manufacturers’ instructions, including hole diameter and minimum engagement
to achieve necessary performance.
! On Stud Wall/Drywall use a good quality Stud Finder to position mounting fasteners in the centre of studs.
! On Masonry wall avoid positioning Wall Plate mounting fasteners in a mortar join.
Please use a
Spirit Level
during installation to
ensure that the Wall Plate is
LEVEL