4. User’s Manual 

·

Examine the oil-level before using to make sure the oil-level is not lower than the 

oil-level line in the sight glass. 

DO NOT RUN PUMP WITH LOW OIL LEVELS. 

Add 

oil to bring it up to the oil level line. This pump uses high-speed vacuum oil HFVM200 

or equivalent. 

·

  Connect the container to be pumped to the gas inlet. The hose should be short, 

sealed and free of dust, dirt and heavy condensation. Check for leaks before 

operating pump.

 

·

Take off the exhaust cap, plug in the power supply and turn the switch to the on 

position. 

·

Unplug the vacuum pump, remove the connecting hoses and cover the exhaust cap 

and oil plug after using. 

 

5. Cautions 

·

Don’t pump flammable, explosive or poisonous gases. 

·

Don’t pump gas that can corrode metals and exert chemical charges. 

·

Don’t pump gas containing any dust or moisture. 

·

The temperature of the pumped gas shouldn’t be over 80

 and the room 

temperature should be around 5

 to 40

 

·

Don’t use vacuum pump as a compression pump. 

·

Pump cannot be run without oil 

·

The operating voltage is between 110V to 115V, 60Hz. You must use a grounded 