  INSTALLATION INSTRUCTIONS

Electrical Connection

A qualified electrician must carry out the electrical installation of this radiator. The electrical installation must comply with 

the current UK and Irish regulations. Any claim on the warranty could be invalid if these requirements have not been met.

The radiator requires a 230/240V 50/60Hz power supply.

Connecting wires:

Brown: Live

Blue: Neutral

Yellow-Green: Earth

The connecting wires must be of the appropriate section, in regards to the length of cable, type of cable and power rating 

of the apparatus.

The apparatus must be connected into a 

fused

 connecting box fitted with an appropriate sized fuse for the radiator – see 

Technical Data on Page 3.

We recommend that the connecting box is positioned 10cm to the right of the apparatus and at 15cm above the floor.

According to regulations, the apparatus must be connected to the power supply by means of an all-pole circuit breaker 

with a contact gap of at least 3mm or by a thermal-magnetic circuit breaker.

Location

The ideal place to site the Sun Ray radiator is as close as possible to coolest wall in the room but it is not recommended 

to site the radiator on un-insulated exterior walls, in this case, the part of the wall behind the radiator should be insulated.

In bathrooms, the radiators must not be sited inside the protected areas. In the UK the heater must be mounted outside 

Zone 2, In Ireland the heater must be mounted outside Zone 3. The control unit switches must not be reachable, directly 

or indirectly, by a person in the bath / shower or using the wash basin.

The radiator, under no circumstances, should be installed below an electric power point.

Choose the location of the radiator in respect of the minimum distances that are indicated in Figure A.

Note: If the window sill protrudes less than 20mm the gap above the heater can be disregarded.

window sill

150mm.

150mm. min.

unobstructed space each side

150mm.

Fig. A

Содержание WF1000 Sun Ray Wifi 1000w

Страница 1: ...n Ray Wifi 500w WF750 Sun Ray Wifi 750w WF1000 Sun Ray Wifi 1000w WF1500 Sun Ray Wifi 1500w WF1800 Sun Ray Wifi 1800w NOTE A qualified electrician must carry out the electrical installation of this ra...

Страница 2: ...ficient convection effect A unique manufacturing process provides bubble free filling so that the fluid delivers warmth from the heating element in a totally uniform way ensuring that the entire surfa...

Страница 3: ...objects within 250mm of the heater In case of breakdown or damage turn off the appliance at the main On Off switch and notify the supplier If the electricity cable gets damaged it must only be replac...

Страница 4: ...onnected to the power supply by means of an all pole circuit breaker with a contact gap of at least 3mm or by a thermal magnetic circuit breaker Location The ideal place to site the Sun Ray radiator i...

Страница 5: ...ned between the second and third elements from each end Fig 1 Fig 2a Fig 3a Fig 2b Fig 3b Place the supports between the elements as shown in Figure 2a mark points on the walls through the fixing hole...

Страница 6: ...he Sun Ray Wifi is designed to be used in conjunction with the SunRay Smart Gateway system and APP providing total control of your radiators from anywhere in the world via the internet The APP is avai...

Страница 7: ...radiator The LCD screen will turn blank and the radiator will lose connection with the Sun Ray Gateway Stand by function Press the Mode OK button until the symbol is present as shown in the following...

Страница 8: ...lect the minutes and confirm pressing OK once more If a radiator is paired with a Sun Ray Gateway time setting is not required as it recognises the system s time automatically Manual Programming Setti...

Страница 9: ...appears on the screen Any button presses will be ignored and bloc will be displayed on the screen To unlock keyboard once again press and hold and for 3 seconds until the word bloc disappears When th...

Страница 10: ...K button and the CONFIG button for 10 seconds The following screen will appear To confirm the reset press OK again to cancel the RESET press any other key Default Values Working mode OFF Comfort Temp...

Страница 11: ...11...

Страница 12: ...p for inspection to establish whether the fault is covered under the guarantee The guarantee is valid in the UK and Ireland only This guarantee is additional to your statutory rights In the unlikely e...

Отзывы: