ATC EcoMini EM Series Скачать руководство пользователя страница 20

 

Applied Thermal Control Ltd 

39 Hayhill Industrial Estate 
Barrow-upon-Soar, Loughborough 
LE12 8LD, United Kingdom 
+44 (0) 1530 839 998 
[email protected] 
[email protected] 

Operating Manual; Warranty Terms 

Annex K-1

 

 

 

DOCUMENT DETAILS 

Date  23/JUN/2020 

Author(s)  RW, MJH 

Page  1 / 1 

Revision  2 

 

WARRANTY TERMS 

 

Please visit the website warranty registration page to ensure ATC can offer you the best possible support; 
 

https://www.app-therm.com/warranty-registration/

 

 
 

a)  For how long is my ATC product warrantied? 

ATC provides a comprehensive return to base 2-year parts, 1-year labor warranty from delivery as 
standard on all new equipment, provided it has been installed and operated in accordance with the 
manual. 
 

b)  Where will ATC fulfill the product warranty?

 

ATC’s standard warranty terms are Return to Base (RTB) – issues with chillers are often easily solvable 
over the phone or email, or by reviewing ATC’s technical guidance on the web and in the product manual. 
On occasion, at the discretion of ATC, goods may be serviced on site FOC or a service loan unit may be 
supplied. Warranty cover excludes the cost of travel by engineers and loan unit rental charges. Obtaining 
onsite service for a product, even in full warranty, is a chargeable service. 
 

c)  Who is liable for shipping charges in the event of warranty failure?

 

During the 

first

 

year

 of the warran

ty period, freight costs for shipping to ATC are for the customer’s 

account. Freight costs for shipping from ATC are for ATC’s account. 
During the 

second

 

year

 

of the warranty, freight costs to and from ATC are for the customer’s account. 

 

d)  I

’m experiencing problems with my chiller. It’s within warranty – what do I do next? 

Contact ATC to discuss the issue you are having. The contact details in the header of this document are 
an ideal place to start. Be sure to have your model number and serial number on-hand to aid those 
attempting to solve remotely. 
 

e) 

Telephone support couldn’t fix my chiller – what do I do next? 

An RMA form must be completed. This allows both the end-user and ATC to clarify your details, to set the 
party responsible for shipping costs, and to set a different return address if desired. Shipping advice is 
provided, and the end-user must sign a declaration that states the unit is safe to handle. Return the form 
by email for fastest response. 
 

f)  What happens if my chiller failed outside warranty or requires non-warranty repair work? 

A purchase order will be requested to cover an initial inspection 

– this will only be invoiced if the inspection 

shows there is no fault. If packaging is required, i.e. a crate, a separate charge will be levied. If the end 
user prefers ATC to arrange a collection, a shipping charge may be levied. 
 

g)  Our process must continue running 

– can we have a loan unit whilst our chiller is in repair? 

ATC hold several standard air-cooled chillers at the factory for the sole purpose of offering for loan 

– these 

are available on a first-come, first-serve basis. Models up-to 3kW capacity are available. 

Annex K-1 200623 Standard warranty terms of ATC

20

Содержание EcoMini EM Series

Страница 1: ...w upon Soar Loughborough LE12 8LD United Kingdom 44 0 1530 839 998 Service thermalexchange co uk Support app therm com Installation Operation Service Manual EcoMini EMxxn DOCUMENT DETAILS Date 28 AUG...

Страница 2: ...Kingdom 44 0 1530 839 998 Service thermalexchange co uk Support app therm com Installation Operation Service Manual EcoMini EMxxn DOCUMENT DETAILS Date 28 AUG 2020 Author s MJH Page 2 5 Revision 1 CHA...

Страница 3: ...C 4 to 35 Optional temp range C 10 to 65 Power supply requirement VAC 100 240 Hz 50 60 A 1 240VAC 2 115VAC Sound pressure level dB 64 Auto diagnostic functions Undertemperature cutout Overcurrent cut...

Страница 4: ...user serviceable parts Repair and service requires specialized knowledge and tools to be provided by ATC or its local agent Any unauthorized tampering with the refrigeration system automatically inval...

Страница 5: ...tallation Mini EcoMini Annex D 2 200828 EcoMini fill procedure Annex E 6 200826 Z31GS Controller Variable Resistor Annex F 1 191129 Pres flow in Mini with centrif pump Annex G 6 200828 EcoMini generic...

Страница 6: ...You should inspect the packaging for signs of transit damage before signing for the unit and if possible unpack the unit before signing Once you have signed for the goods ATC cannot be held responsibl...

Страница 7: ...ltage b Frequency of 47Hz to 63Hz inclusive c Maximum current draw of 5 8A 100VAC mains fusing is rated 6 3A accessible from rear i See product rating label for fuse specification ii Two modes of supp...

Страница 8: ...Mini and EcoMini are supplied with quick release fittings by default either of the CPC or push fit variety The former of these have built in valves to prevent loss of fluid when disconnecting but oth...

Страница 9: ...n water line and where the lid seals c Turn your attention to the power inlet rocker switch on the back of the chiller i Immediately after toggling this switch assuming that the power cord is connecte...

Страница 10: ...ATION VALUE ON Z31 GS Navigation Upon first powering on the chiller will arrive at this display after a loading sequence is complete Process cooling will start automatically on the fridge and water ci...

Страница 11: ...4 Regardless of the position of the speed dial the low temperature cutoff controller will stop the compressor if the process water temperature falls below its set value and will not start again until...

Страница 12: ...are best served by the quieter and mechanically looser centrifugal types the flow of these items is dictated by the backpressure of the pipework through which it must pump Reviewing the pump flow cur...

Страница 13: ...ing fan the compressor or the pump Pay attention to specific components to identify the source of noise If there is an air pocket within the water circuit or not enough liquid in the tank the pump cou...

Страница 14: ...thly J F M A M J J A S O N D Check the condenser is free from dust or accumulation of debris Annually Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Drain process fluid and replace with fresh fluid Check for fluid leaks thr...

Страница 15: ...ing fan blades continue to rotate Do not attempt servicing whilst the blades are rotating Warning All chillers contain water and electricity in close proximity Ensure the unit is isolated before servi...

Страница 16: ...mber Commercial name As above NOTIFIED BODY Not applicable QUALITY ASSURANCE SYSTEM QMS International Ltd Muspole Court Muspole Street Norwich NR3 1DJ United Kingdom ASCB Registered 201409 2 DECLARATI...

Страница 17: ...strate compliance upon request with the Conflict Minerals acts and guidelines ATC uses Gold and Tin in electrical components on PCBs and in rotating machinery as governed by technical requirements of...

Страница 18: ...an be used in some uses but cannot be used in identified uses Applied Thermal Control has contacted all our suppliers and to the best of our knowledge none of the articles that we sell intentionally c...

Страница 19: ...sks posed by these substances alone The European Parliament and Council issued regulation 2019 1021 on 20 JUN 2019 and further amended regulation 2020 784 on 8 APR 2020 POPs LISTED UNDER INITIAL REGUL...

Страница 20: ...account Freight costs for shipping from ATC are for ATC s account During the second year of the warranty freight costs to and from ATC are for the customer s account d I m experiencing problems with...

Страница 21: ...Condenser Fan 1 EA512 Power Inlet Fuse 2 EA769 Pump Fuse 1 EA764 DIN Rail Fuse Holder 1 WA643 Self Sealing Water Bulkhead SA00016 2 WA644 Self Sealing Water Connectors SA00016 2 WA642 12mm Push Fit Wa...

Страница 22: ...d use SU21 Consumer uses Private households general public consumers Description Gas 1 3 Details of the supplier of the safety data sheet Company Harp International Limited Address Gellihirion Industr...

Страница 23: ...medical attention if irritation or symptoms persist Eye contact Seek medical attention if irritation or symptoms persist Skin contact Frostbite treat as thermal burns Ingestion Ingestion is not consi...

Страница 24: ...f ignition No smoking Do not eat drink or smoke in areas where this product is used or stored When using do not eat or drink Wash hands after handling the product 7 2 Conditions for safe storage inclu...

Страница 25: ...Odour Slight Odour threshold No data available Freezing Point No data available Evaporation rate No data available Water solubility No data available Fat Solubility No data available Soluble in No dat...

Страница 26: ...high temperature Thermal decomposition giving toxic and corrosive products Gaseous hydrogen fluoride HF Carbon oxides Decomposition temperature 370 C SECTION 11 Toxicological information 11 1 Informat...

Страница 27: ...bal warming potential with respect to CO2 1430 IPCC Assessment Report 4 Ozone depletion potential Ozone depletion potential ODP R 11 1 Value SECTION 13 Disposal considerations 13 1 Waste treatment met...

Страница 28: ...y amending Directive 1999 45 EC and repealing Council Regulation EEC No 793 93 and Commission Regulation EC No 1488 94 as well as Council Directive 76 769 EEC and Commission Directives 91 155 EEC 93 6...

Страница 29: ...ician 4 2 Skin Contact Wash off immediately with plenty of water If skin irritation persists call a physician 4 3 Inhalation Remove to fresh air If symptoms persist call a physician 4 4 Ingestion Rins...

Страница 30: ...Time Weighted Average TWA Particulate 10 mg m3 ELV IE Time Weighted Average TWA Total vapour and particulates 150 ppm 470 mg m3 ELV IE Time Weighted Average TWA Particulate 10 mg m3 8 2 Exposure cont...

Страница 31: ...tion to the nose throat upper respiratory tract and lungs No deaths occurred 11 3 Dermal LD50 20000 mg kg rabbit Prolonged skin contact is unlikely to result in absorption of harmful amounts Skin irri...

Страница 32: ...pty contaminated packaging thoroughly They can be recycled after thorough and proper cleaning Packaging that cannot be cleaned are to be disposed of in the same manner as the product 13 3 European Was...