Employment of the charging pump
Mount a stainless steel hook above the buffer tank.
Prepare the charging pump with angled hose
nozzle, PVC hose (40 mm) and chain. The chain is
already secured to the pump handle using a
shackle.
The float switch is also attached to the handle
using two cable clips. The switch-OFF point should
lie approximately at the height of the centre of the
pump.
Please take care that the float switch moves freely
upwards and downwards and cannot jam.
For better handling hose, chain and cable are fixed
using cable straps.
Hang the pump ca. 5 cm above the sole in the
buffer tank. Here also take care that the pump is
not located to near the tank wall in order to ensure
the free movement of the float switch.
Secure the distributor box with the connection
cable to the cone.
Roll up the freely hanging cable and hang it up in
the OBO grip.
Pull the charging hose through the connecting pipe
in the SBR tank and secure the end to the cover
using a plastic clip.
Please ensure that you take care that
the free end of the charging hose
does not dip into the water in the SBR
tank or can submerge in order to
avoid a syphon effect (communicating
pipes)!