![AT&T Bell System 7A Скачать руководство пользователя страница 86](http://html.mh-extra.com/html/atandt/bell-system-7a/bell-system-7a_manual_2993729086.webp)
SECTION 5 1 8-450- 1 00
TABLE
0
(Coni)
TROUBLE ANALYSIS TABLE
TROUBLE
POSSI BLE CAUSE
POSSI BLE SOLUTION
a.
457C KTU is not plugged in
Check that KTU is properly seated and
correctly.
is in right connector.
See Fig. 42.
b.
Speakers wired wrong.
Check connections.
See Fig. 43.
Cannot
c.
Defective speaker.
Replace speaker.
transmit over
d.
Wrong speaker used.
Use only 45-ohm speakers.
paging
Speaker located too far from
Use quad wire. Speaker should be
speakers.
e.
KSU.
within 320 feet of KSU.
f.
Potentiometer in K8 speaker
Adjust potentiometer.
turned too low.
a.
457C KTU is not plugged in
Check that KTU is properly seated and
correctly.
is in right connector.
See Fig.
6
and 42.
b.
Potentiometer in 20A-49
Adjust potentiometer.
apparatus unit turned too
low.
c.
Customer's paging system turned
Proceed as follows :
off
1.
Test for hazardous voltages at
Cannot
transmit over
or
terminals Al and A2 of 20A-49
COAM paging
apparatus unit.
system.
Trouble in COAM paging
2.
Remove customer's connections from
terminals Al and A2.
equipment.
3.
Have attendant dial paging code.
4.
Monitor across terminals Al and A2
with 1013A test set.
5.
If attendant can be heard with
1013A test set, advise customer of
results of test.
Do 11ot
attempt any
tests or repairs on customer's
equipment.
Page 86