![AT&T Bell System 7A Скачать руководство пользователя страница 110](http://html.mh-extra.com/html/atandt/bell-system-7a/bell-system-7a_manual_2993729110.webp)
SECTION
5 1 8-450-1 00
TABLE Z
I NPUTS AND OUTPUTS-424B/424C KTU
TEST
TO
MON/TALK
FROM
SWITCH
TEST FOR
REMARKS
I NPUTS
Jl0-18
A Battery
GROUND
TALK
Jl0-17
B Battery
J18-17
J9-1 5
B Ground
TALK
J18-18
Jl0-3
A Ground
OUTPUTS
1 sec. tone burst on VS lead of
Tone burst heard after
GROUND
VS lead
MON
station tested. See Fig. 70 for VS
dialing proper digit(s)
lead assignment.
Jl0-19
Ground - BYl lead
Dialing complete-
1- or 2-digit code
B BAT
After dialing 1st digit,
Jl0-30
TALK
Ground - LK lead
dial tone should be
removed
Jl0-39
Ground - TTG lead
Selector seized
GROUND
Jl0-35
B BAT. - BR lead
Selector seized
Page 1 1 0