GENERAL

Carefully read the following important information regarding installa-

tion safety and maintenance. Keep this information booklet accessible

for further consultations.

The appliance has been designed as a suction version (external ex-

haust) or as a filter version (internal air recycle) cooker hood.

SAFETY PRECAUTION

1. 

ake care when the cooker hood is operating simultaneously with an

open fireplace or burner that depend on the air in the environment and

are supplied by other than electrical energy, as the cooker hood re-

moves the air from the environment which a burner or fireplace need for

combustion.

The negative pressure in the environment must not exceed 4 Pa (4 x 10

-5 bar).

Provide adequate ventilation in the environment for a safe operation of

the cooker hood.

Follow the local laws applicable for external air evacuation.

2.  WARNING!!

In certain circumstances electrical appliances may be a danger

hazard.

A) Do not check the status of the filters while the cooker hood

is operating

B) Do not touch the light bulbs after appliance use

C) Flambè cooking is prohibited underneath the cooker hood

D) Avoid free flame, as it is damaging for the filters and a fire

hazard

E) Constantly check food frying to avoid that the overheated oil

may become a fire hazard

F) Disconnect the electrical plug prior to any maintenance.

INSTALLATION INSTRUCTIONS

• 

Electric Connection

The appliance has been manufactured as a class II, therefore no earth

cable is necessary.

The connection to the mains is carried out as follows:

BROWN = 

L

 line

BLUE = 

N

 neutral

If not provided, connect a plug for the electrical load indicated on the

description label. Where a plug is provided, the cooker hood must be

installed in order that the plug is easily accessible.

An omnipolar switch with a minimum aperture of 3mm between con-

tacts, in line with the electrical load and local standards, must be placed

between the appliance and the network in the case of direct connection

to the electrical network.

• 

The appliance must be installed at a minimum height of 700 mm from

an cooker stove in case of a gashob or an electrical hob.

If a connection tube composed of two parts is used, the upper part must

be placed outside the lower part.

Do not connect the cooker hood exhaust to the same conductor used to

circulate hot air or for evacuating fumes from other appliances gener-

ated by other than an electrical source.

• 

MOUNTING OF THE HOOD IN THE LOWER PART OF AN

HANGING CUPBOARD
This appliance has to be built in the lower part of an hanging cupboard
or in another support. For the fixing use 4 screws, which are appropri-
ate to thakind of cupboard, drilling the holes corresponding to fig.1 and
2.

CHANGING FROM EXHAUSTING HOOD TO FILTERING ONE
In order to make this change (possible also after the use of the
exhausting system), demand a set of carbon filters (F)  fig. 3  to your
dealer. Active carbon filters are necessary to depurate the air, that will
be released in the room. Filters are not washable; they cannot be
regenerated and have to be replaced at most every 4 months. The
saturation of the activated charcoal depends on the more or less
prolonged use of the hood, on the type of cooking and on the regularity
of cleaning of the grease filter. The filter has to be applied to the

aspirating group, which is inside the hood hiting the centre of the group
with it and turning it of 90 degrees until the stop click is heard to lock
it fig. 3. Remove the grills (G) fig. 3 to carry out this operation. The air
is released in the room through a connecting pipe, which goes through
the hanging cupboard and which is connected to the connecting ring
supplied (B) fig. 1.

USE AND MAINTENANCE

• 

It is recommended to operate the appliance prior to cooking.

It is recommended to leave the appliance in operation for 15 minutes

after cooking is terminated in order to completely eliminate cooking

vapours and odours.

The proper function of the cooker hood is conditioned by the regularity

of the maintenance operations, in particular, the active carbon filter.

• 

The anti-grease filters capture the grease particles suspended in the

air, and are therefore subject to clogging according to the frequency

of the use of the appliance.

In order to prevent fire hazard, it is recommendable to clean the filter

at a maximum of 2 months by carrying out the following instructions:

- Remove the filters from the cooker hood and wash them in a solution

of water and neutral liquid detergent, leaving to soak.

- Rinse thoroughly with warm water and leave to dry.

- The filters may also be washed in the dishwasher.

The aluminium panels may alter in colour after several washes. This is

not cause for customer complaint nor replacement of panels.

• 

The active carbon filters purify the air that is replaced in the environ-

ment.  The filters are not washable nor re-useable and must be replaced

at maximum every four months. The saturation of the active carbon filter

depends on the frequency of use of the appliance, by the type of cooking

and the regularity of cleaning the anti-grease filters.

• 

Clean the fan and other surfaces of the cooker hood regularly using

a cloth moistened with denatured alcohol or non abrasive liquid deter-

gent.

THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR

EVENTUAL DAMAGES CAUSED BY BREACHING THE ABOVE

WARNINGS.

ENGLISH

Содержание WU7011AM

Страница 1: ...anwijzing en installatievoorschrift afzuigkap mode d emploi et d installation hotte de cuisine Montage und Bedienungsanleitung Dunstabzugshaube instructions for use and installation cooker hood WU7011AM WU5011AM ...

Страница 2: ...2 Fig 1 Fig 2 Fig 3 257 494 200 57 273 521 247 62 174 285 525 705 B G 90 F M ...

Страница 3: ...te van een keukenkastje of in ander geschikt meubilair Voor de bevestiging dient u vierschroeventegebruikendiegeschiktzijnvoorhettypemeubel waarbij gaten geboord dienen te worden zoals blijkt uit fig 1 en fig 2 Dit apparaat moet aan de onderzijde van een keukenkastje gemonteerd worden Gebruik hiervoor vier schroeven die geschikt zijn voor het type kastje De gaten maken volgens het schema in fig 1 ...

Страница 4: ...rée dans un élément haut ou un autre support Pour la fixation de la hotte utiliser 4 vis appropriées au type de meuble en percant les trous correspondants à la fig 1 et 2 TRANSFORMATION DE LA HOTTE ASPIRANTE EN HOTTE FILTRANTE Poureffectuercettetransformation possiblemêmeaprèsl emploide la hotte avec le système aspirant commander à votre fournisseur unesériedefiltresaucharbonactif F fig 3 Lesfiltr...

Страница 5: ...ube ausführen MONTAGE DER HAUBE UNTER DEM HÄNGESCHRANK Dieses Gerät muß an der Unterseite eines Hängeschrankes oder einesanderenMöbelsbefestigtwerden Hierzusind4Schraubenzu verwenden die der Beschaffenheit des Möbels angemessen sind LöchergemäßAbb 1und2bohren UMBAU DER AUBZUGSHAUBE IN UMLUFTHAUBE ZurDurchführungdiesesUmbaus auchnachGebrauchderAbzugs haubemöglich sindbeimHändlereinigeAktivkohlefilt...

Страница 6: ...angingcupboard orinanothersupport Forthefixinguse4screws whichareappropri atetothakindofcupboard drillingtheholescorrespondingtofig 1and 2 CHANGING FROM EXHAUSTING HOOD TO FILTERING ONE In order to make this change possible also after the use of the exhausting system demand a set of carbon filters F fig 3 to your dealer Activecarbonfiltersarenecessarytodepuratetheair thatwill be released in the ro...

Страница 7: ...3LI0CCA7 ...

Отзывы: